| 2007-08-15 21:18:02 | GOODRICH LLC CITY PL. TOWER SUITE # 1000 |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07070352 |
| | ADD: 525 OKEECHOBEE BLVD # 1000 |
| | CONT: DAVIS GENERAL CONTRACTING CORP |
| | TEL: (561) 820-1400 |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) BASED ON THE DETERMINATION OF THE BUILDING OFFICIAL, |
| | APPLICATION FOR TENANT IMPROVEMENT PRIOR TO C.O. WILL |
| | REQUIRE SHOP DRAWING REVIEW BY THE BASE BUILDING DESIGN |
| | TEAM, THE DESIGNER OF RECORD. PLEASE HAVE THE BASE |
| | BUILDING DESIGNERS OF RECORD REVIEW YOUR PLANS AND IF |
| | FOUND SUFFICIENT AFFIX THEIR SHOP DRAWING STAMP ON YOUR |
| | DOCUMENTS. |
| | NOTE ALSO THAT A TENANT CAN NOT ACHIEVE A CERTIFICATE |
| | OF OCCUPANCY BEFORE THE SHELL BUILDING HAS RECEIVED |
| | THEIR CERTIFICATE OF COMPLETION. FBC 106.1.2* |
| | ADMINISTRATIVE CODE. |
| | |
| | 3)PLEASE NOTE AT THIS TIME THIS BUILDING HAS NOT |
| | RECEIVED A CERTIFICATE OF COMPLETION, AND THE ENERGY |
| | CALCULATIONS ARE BASED ON A SHELL BUILDING AND ARE |
| | BASED ON 13-101.1.6. UNLESS THE BUILDING IS COMPLETED |
| | AS PER ALL ASSUMPTIONS MADE IN THE ORIGINAL CODE |
| | COMPLIANCE SUBMITTAL, REVISED CODE SUBMITTALS USING |
| | METHOD A, B OR C SHALL BE SUBMITTED WHEN THE COMPLETION |
| | OF THE BUILDING (OR PART) OF A BUILDING IS PERMITTED. |
| | |
| | 4)PLEASE CONTACT LILI URSA AT 822-1239 FOR SUITE |
| | NUMBER ASSIGNMENT PLEASE PROVIDE THIS INFORMATION IN |
| | THE TITLE BLOCK, SEE FLORIDA ADMINISTRATIVE CODES |
| | 61G1-15.004 AND 61G15-23.002. |
| | |
| | 5) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION |
| | THAT IS REQUIRED FOR RECORD KEEPING & FOR CERTIFICATE |
| | OF OCCUPANCY, TO BE LISTED IN THE PLAN: |
| | A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT |
| | IS DESIGNED. |
| | B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE |
| | PROVISIONS OF CHAPTER 3. |
| | C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER 6, |
| | TABLE 601. |
| | D) THE OCCUPANT LOAD, SEE 1004. |
| | E) IF AN AUTOMATIC SPRINKLER SYSTEM ISPROVIDED F) |
| | WHETHER THE SPRINKLER SYSTEM IS REQUIRED. |
| | G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE |
| | BUILDING PERMIT |
| | |
| | 6A) SHEET ID-1A WALL TYPE "A" IS INDICATED AS AN |
| | EXISTING CMU DEMISING WALL, PLEASE COORDINATE WITH THE |
| | BASE BUILDING DESIGNER. ADDITIONAL INFORMATION |
| | REQUIRED, FBC ADMINISTRATIVE CODE 106.1.2*. THE SHELL |
| | BUILDING PLAN SHEET A1.06 & A2.06 BOTH INDICATE THIS |
| | WALL TO BE A DRYWALL AND METAL STUD WALL. |
| | |
| | 6B) SHEET ID-1A ALSO INDICATES THE TENANT SEPERATION |
| | WALLS TO BE EXISTING CMU DEMISSING WALL.THE BASE |
| | SHELL BUILDING PLAN DOESN'T INDICATE ANY SUCH WALL. |
| | 708.1(5) REQUIRES FIRE PARTITIONS BETWEEN TENANTS. |
| | 708.3 FIRE RESISTANCE RATING WILL REQUIRE A 1-HOUR FIRE |
| | RATING. |
| | FLORIDA STATE STATUTE 481.2131 INTERIOR DESIGNER CAN |
| | NOT DESIGN PLANS OR PORTIONS OF THAT EFFECT FIRE-RATED |
| | SEPERATIONS BETWEEN INTERIOR SPACES, THE FIRM IS |
| | WORKING OUT OF THE SCOPE OF THEIR LOCENSE. SEE |
| | ATTACHMENT 481.2131. |
| | |
| | 7) SHEET ID-1A DOOR# 002IS INDICATED TO BE A SINGLE |
| | 2'-8" DOOR CUT IN HALF, CLOSETS THAT AREDEEPER THAN |
| | 2'-0" WILL REQUIRE A MINIMUM CLEAR WIDE OF 32" WHEN THE |
| | DOOR OR DOORS ARE OPEN 90 DEGREES TO THE OPENING. SEE |
| | 11-4.13.5 |
| | 11-4.13.5 CLEAR WIDTH. |
| | DOORWAYS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 |
| | INCHES (813 MM) WITH THE DOOR OPEN 90 DEGREES, MEASURED |
| | BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE STOP [SEE |
| | FIGURE 24 (A), FIGURE 24 (B), FIGURE 24 (C), AND FIGURE |
| | 24 (D)]. OPENINGS MORE THAN 24 INCHES (610 MM) IN DEPTH |
| | SHALL COMPLY WITH SECTIONS 11-4.2.1 AND 11-4.3.3 [SEE |
| | FIGURE 24 (E)]. |
| | EXCEPTION: DOORS NOT REQUIRING FULL USER PASSAGE, SUCH |
| | AS SHALLOW CLOSETS, MAY HAVE THE CLEAR OPENING REDUCED |
| | TO 20"MINIMUM. |
| | |
| | 8) SHEET ID-1A DOORS 023 AND 024 ARE BOTH CLOSET DOORS |
| | THAT OPEN TO A CLOSET DEEPER THAN 24" REQUIRING A CLEAR |
| | 32" OPENING. |
| | SEE 11-4.13.5 CLEAR WIDTH. |
| | |
| | 9) DOORS 16-19 ARE INDICATED AS 28" DOORS THAT LEAD TO |
| | THE INDIVIDUAL WATER CLOSET STALLS.PLEASE SEE 11-4.13.5 |
| | AND 11-4.17.5 |
| | DOORS. TOLIET STALL DOORS INCLUDING DOOR HARDWARE, |
| | SHALL COMPLY WITH SECTION 11-4.13.. DOORS SHALL BE SELF |
| | CLOSING. |
| | 11-4.17.3 EXCEPTION: NEW CONSTRUCTION. |
| | (1)THE STANDARD ACCESSIBLE RESTROOM STALL SHALL |
| | CONTAIN AN ACCESSIBLE LAVATORY WITHIN IT, THE SIZE OF |
| | SUCH LAVATORY TO BE NOT LESS THAN 19 INCHES WIDE BY 17 |
| | INCHES (483 MM BY 432 MM) DEEP, NOMINAL SIZE, AND WALL |
| | MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT TO |
| | OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY SECTION |
| | 11-4.17 [SEE FIGURE 30 (A) AND FIGURE 30 (E)] AND TO |
| | COMPLY WITH SECTION 11-4.19 OF THE CODE. SUCH |
| | LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED |
| | FIXTURE COUNT FOR THE BUILDING. |
| | (2)THE ACCESSIBLE WATER CLOSET SHALL BE LOCATED IN |
| | THE CORNER, DIAGONAL TO THE DOOR. |
| | |
| | 10) IN BOTH THE WOMEN'S AND MEN'S RESTROOMS THERE ARE |
| | NO HANDICAPPED STALLS. 11-4.1.3(11)TOILET FACILITIES. |
| | IF TOILET ROOMS ARE PROVIDED, THEN EACH PUBLIC AND |
| | COMMON USE TOILET ROOM SHALL COMPLY WITH SECTION |
| | 11-4.22 . |
| | EXCEPTION: NEW CONSTRUCTION. |
| | (1)THE STANDARD ACCESSIBLE RESTROOM STALL SHALL |
| | CONTAIN AN ACCESSIBLE LAVATORY WITHIN IT, THE SIZE OF |
| | SUCH LAVATORY TO BE NOT LESS THAN 19 INCHES WIDE BY 17 |
| | INCHES (483 MM BY 432 MM) DEEP, NOMINAL SIZE, AND WALL |
| | MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT TO |
| | OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY SECTION |
| | 11-4.17 [SEE FIGURE 30 (A) AND FIGURE 30 (E)] AND TO |
| | COMPLY WITH SECTION 11-4.19 OF THE CODE. SUCH |
| | LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED |
| | FIXTURE COUNT FOR THE BUILDING. |
| | (2)THE ACCESSIBLE WATER CLOSET SHALL BE LOCATED IN |
| | THE CORNER, DIAGONAL TO THE DOOR. |
| | |
| | 11) SHEET ID-14 DETAIL A1 BREAK ROOM# 112 SINKS: |
| | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL BE MOUNTED WITH |
| | THE COUNTER NO HIGHER THAN 34" ABOVE THE FINISH FLOOR. |
| | 11-4.24.3 KNEE CLEARANCE THAT IS AT LEAST 27" HIGH 30" |
| | WIDE, AND 19" DEEP SHALL BE PROVIDED UNDERNEATH SINKS. |
| | 11-4.24.5 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE AT |
| | LEAST 30 INCHES BY 48 INCHES (760 MM BY 1219 MM) |
| | COMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED IN |
| | FRONT OF A SINK TO ALLOW FORWARD APPROACH. THE CLEAR |
| | FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL |
| | EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE |
| | SINK. |
| | |
| | 12)SHEET ID-14 DETAIL A11 & A15 BOTH ARE OF RESTROOM |
| | VANITIES AND LAVATORIES.11-4.19.2 HEIGHT AND |
| | CLEARANCES. |
| | LAVATORIES SHALL BE MOUNTED WITH THE RIM OR COUNTER |
| | SURFACE NO HIGHER THAN 34 INCHES (865 MM) ABOVE THE |
| | FINISH FLOOR. PROVIDE A CLEARANCE OF AT LEAST 29 INCHES |
| | (735 MM) ABOVE THE FINISH FLOOR TO THE BOTTOM OF THE |
| | APRON. KNEE AND TOE CLEARANCE SHALL COMPLY WITH FIGURE |
| | 31 . |
| | |
| | 11-4.19.3 CLEAR FLOOR SPACE. |
| | A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES (760 MM BY |
| | 1219 MM) COMPLYING WITH SECTION 11-4.2.4 SHALL BE |
| | PROVIDED IN FRONT OF A LAVATORY TO ALLOW FORWARD |
| | APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR |
| | OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM |
| | OF 19 INCHES (485 MM) UNDERNEATH THE LAVATORY (SEE |
| | FIGURE 32 ). |
| | |
| | 11-4.19.4 EXPOSED PIPES AND SURFACES. |
| | HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE |
| | INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST |
| | CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES |
| | UNDER LAVATORIES. |
| | |
| | 13)TABLE 803.3 MINIMUM INTERIOR FINISH |
| | CLASSIFICATION; PROVIDE INFORMATION BASED ON INTERIOR |
| | FINISH REQUIREMENTS BASED ON OCCUPANCY. |
| | |
| | 14) ON THE INTERIOR ELEVATION SHEETS QUITE A FEW WALLS |
| | INDICATE THE USE OF UPHOLSTERED PANELS, PLEASE PROVIDE |
| | ADDITIONAL INFORMATION 106.1.2.HOW WILL THE FABRIC BE |
| | MOUNTED? 803.6.1 TEXTILE WALL COVERINGS. |
| | TEXTILE WALL COVERINGS SHALL HAVE A CLASS A FLAME |
| | SPREAD INDEX IN ACCORDANCE WITH ASTM E 84 AND BE |
| | PROTECTED BY AUTOMATIC SPRINKLERS INSTALLED IN |
| | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2 OR THE |
| | COVERING SHALL MEET THE CRITERIA OF SECTION 803.6.1.1 |
| | OR 803.6.1.2 WHEN TESTED IN THE MANNER INTENDED FOR USE |
| | IN ACCORDANCE WITH NFPA 265 USING THE PRODUCT MOUNTING |
| | SYSTEM, INCLUDING ADHESIVE. |
| | |
| | 15) THE MILLWORK LEGEND INDICATES CATALOG NUMBERS FOR |
| | TRIM BUT DOESN'T IDENTIFY AS TO WHAT TYPE OF MATERIALS |
| | THE TRIM WILL BE MADE OF? 106.1.2* ADDITIONAL |
| | INFORMATION REQUIRED.805.5 TRIM . |
| | MATERIAL USED AS INTERIOR TRIM SHALL HAVE A MINIMUM |
| | CLASS C FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX. |
| | COMBUSTIBLE TRIM , EXCLUDING HANDRAILS AND GUARDRAILS, |
| | SHALL NOT EXCEED 10 PERCENT OF THE AGGREGATE WALL OR |
| | CEILING AREA IN WHICH IT IS LOCATED. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |