| Plan Review Notes For Permit 07070345 |
| Permit Number |
07070345 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2007-08-27 13:49:26 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)AN EDGE DISTANCE OF 3" REQUIRES A .86 FACTOR.YOU | | | HAVE HIGHLIGHTED THIS ON THE PRODUCT APPROVAL BUT DID | | | NOT APPLY THIS FACTOR TO THE ANCHOR SPACING ON THE | | | INSTALLATION SCHEDULE. | | | | | | 2.)SPECIFY THE SIDE ANCHOR SPACING ON THE | | | INSTALLATION SCHEDULE. | | | | | | 3.)ENGINEERING SOFTWARE REFERS TO ASCE7-05.CORRECT | | | VERSION IS 7-02, FBC35. |
|