| 2007-09-04 10:49:37 | CONSTRUCTION SERVICES DEPARTMENT |
| | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, |
| | FLORIDA33401 |
| | TEL:561-805-6713FAX: |
| | 561-805-6731 |
| | |
| | JAMES JOHNSTON,CBO PERMIT NO. 07070315 |
| | BUILDING PLAN EXAMINERII ADDRESS 9055 IBIS |
| | E-MAIL:JJOHNSTON @WPB.ORG PROJECT: KITSON |
| | CORPORATE OFFICE CONTRACTOR: SHAKMAN |
| | HOSPITALITY LLC |
| | DATE: AUGUST30,2007 |
| | |
| | PLANREVIEW |
| | |
| | 109.3.10.1HURRICANE PROTECTION |
| | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW |
| | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO |
| | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION |
| | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN |
| | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN |
| | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| | DEBRIS SHALL BE EITHER REMOVED FROM THE CONSTRUCTION |
| | SITE OR SECURED IN SUCH A MANNER AS TO MINIMIZE THE |
| | DANGER OF SUCH CONSTRUCTION MATERIALS, EQUIPMENT AND |
| | DEBRIS CAUSING DAMAGE TO PERSONS OR PROPERTY FROM HIGH |
| | WINDS. |
| | ANY PERSONS WHO FAIL TO COMPLY TO REMOVE OR SECURE THE |
| | CONSTRUCTION MATERIALS, EQUIPMENT AND DEBRIS WITHIN 24 |
| | HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE |
| | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION TO |
| | THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS |
| | SECTION SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO |
| | SECTION 113 OF THIS CHAPTER. |
| | |
| | SUBMITTING PLAN CORRECTIONS |
| | WHEN RE-SUBMITTING PLANS WITH CORRECTIONS PLEASE |
| | PROCEED AS FOLLOWS: |
| | A.INDICATE THE CORRECTED ITEMS BY CLOUDING ON THE |
| | NEW CORRECTED SHEET |
| | B.REMOVE THE OLD SHEET FROM THE PLAN AND INSERT THE |
| | NEWLY CORRECTED SHEET |
| | C.PUT OLD THE OLD SHEETS TOGETHER AS ONE SET AND |
| | SUBMIT TO THE BUILDING DEPT. ALONG |
| | WITH THE NEW CORRECTED PLANS. THIS IS NECESSARY |
| | FOR THE PLAN REVIEWER TO CRITIQUE |
| | THE CORRECTION REQUIRED FROM THE PREVIOUS PLAN |
| | REVIEW. |
| | D.SUBMIT A COVER LETTER IDENTIFYING THE CORRECTION |
| | MADE LISTING THE ITEM REFERENCED |
| | IN THE REVIEWER?S COMMENTS. |
| | |
| | 61G1-16.004TITLE BLOCK |
| | LANDSCAPE ARCHITECT? URBAN DESIGN STUDIOS |
| | A TITLE BLOCK ON ALL ARCHITECTURAL OR INTERIOR DESIGN |
| | DRAWINGS AND SPECIFICATION INDICATION SHEETS. THE TITLE |
| | BLOCK MUST AT A MINIMUM CONTAIN THE FOLLOWING |
| | INFORMATION: |
| | FIRM NAME,ADDRESS,TELEPHONE NUMBER |
| | FIRM LICENSE NUMBER,CERTIFICATE OF AUTHORIZATION NAME |
| | OR IDENTIFICATION OF PROJECT |
| | DATE PREPARED |
| | A SPACE FOR THE SIGNATURE AND DATED SEAL |
| | A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING THE |
| | DOCUMENT |
| | |
| | |
| | ICE ? INTERNATIONAL CONSULTING ENGINEERS, INC. |
| | UP-DATE YOUR ADDRESS. IT DOES NOT CONFORM TO THE DBPR |
| | RECORDS |
| | |
| | 2. FBC506.2506.3AREA INCREASE |
| | NOTE ON PLAN ALLOWED PER CODE DEFINED |
| | |
| | WINDOWS / DOORS PRODUCT APPROVALS |
| | PRODUCT APPROVALS ARE REQUIRED FOR WINDOWS / |
| | DOORS/MULLIONS/ROOFING ASSEMBLIES |
| | WPB ADMINISTRATIVE CODE 106.3 REGULATED BY DCA RULE |
| | 9B-72FLORIDA PRODUCT APPROVAL |
| | SUBMIT TWO COPIES OF EACH APPROVAL WITH |
| | FLORIDA PRODUCT APPROVAL COVER SHEET THE ARCHITECT?S / |
| | ENGINEER?S SIGNATURE AS APPLICABLE, STATING TO THE BEST |
| | OF THEIR KNOWLEDGE THE |
| | PRODUCT APPROVAL COMPLIES WITH THE PLANS |
| | AND SPECIFICATIONS.SEE:WEB SITE |
| | WWW.FLORIDABUILDING.COM |
| | NOTE: SEE DIVISION FACTOR TO BE USED IN DESIGN |
| | PRESSURE BY LEGACYFPA |
| | |
| | SUBMIT PRODUCT APPROVALS WIDTH FLORIDA |
| | PRODUCT APPROVAL COVER |
| | PAGE FOR THE FOLLOWING |
| | FIXED GLASS |
| | MULLION TUBES |
| | STORE FRONT GLAZING SYSTEM |
| | ALUMINUM OUT SWING DOORS |
| | HOLLOW METAL DOORS |
| | TRUSS ANCHORS |
| | |
| | FBC13-100.2 ENERGY CALCULATIONS |
| | COVER SHEET ENERGY CALCULATIONS INFORMATION. THIS IS A |
| | 2 STORY BUILDING |
| | COMPLETE OWNER AND ADDRESS INFORMATION |
| | FIRST FLOOR UN-FINISHED |
| | SECOND FLOOR FINISHED |
| | ENTER CORRECT SQUARE FOOTAGE FIRST AND |
| | SECOND FLOOR |
| | |
| | FBC-13-400. A METHOD A IS FOR A COMPLETED |
| | BUILDING AND STATES ( 2NDPARAGRAPH) EXCEPT |
| | DESIGNS WITH NO MECHANICAL SYSTEM. |
| | FBC-13-400.2.A.2 SHELL BUILDING ON THE FIRST FLOOR |
| | FBC-13-400.3.C METHOD CFOR THE 2ND FLOOR |
| | ZONE 1IS THE LOBBY NOT RECEPTIONIST AREA |
| | WINDOWTYPE A ON FIRST FLOOR(44) NOT 40 |
| | COMPLETE ALL ITEMS WITH CORRECT INFORMATION |
| | |
| | FBCTABLE 1609.6.2 (14)MEAN ROOF HEIGHT |
| | USE 40 FEET. PROVIDE ON PLAN EXPOSURE B, |
| | ADJUSTMENT FACTOR 1.09 |
| | FBCTABLE 1609.6.2 (12)NET DESIGN WIND PRESSURE |
| | |
| | PRODUCT APPROVALS |
| | ROOF TILEPRODUCT APPROVAL LEGACYREPORT |
| | PLAN STATES SPANISH SROOF TILE |
| | TABLE 3 PAGE 8 OF 12 EXPOSURE BWIND LOADS |
| | AT 140 MPH, MEAN ROOF HEIGHT 40,UPLIFT28 |
| | BASED ON THIS INFORMATION, HIGHLIGHT |
| | FASTENERS TO BE USED ON USED ON TABLE 2 SCHEDULE |
| | TAMKO FLORIDA PRODUCT APPROVAL HAS EXPIRED |
| | |
| | CANOPIES |
| | STATE ON PLANS ?ALL CANOPIES UNDER SEPARATE |
| | PERMIT? |
| | |
| | 1906.2.2.1SHORING & RESHORING |
| | SUBMIT PLAN FOR REMOVAL OF SHORES AND |
| | RE-SHORING |
| | |
| | SHEET S-4 |
| | STRUCTURAL NOTES - INCLUDE THE STATEMENT 2004 |
| | FBC WITH 2006 SUPPLEMENTS |
| | |
| | SHEETLS-1 |
| | NOTE ON PLAN AREA INCREASE ALLOWEDFBC-506.2 & |
| | 506.3 |
| | |
| | FBC -3006.1 ELEVATOR MACHINE ROOM |
| | CAN?T HAVE A MACHINE ROOM LOCATED IN A TENANT SPACE |
| | |
| | ELEVATOR PITWATERPROOFINGFBC1802.2.3 FBC |
| | 1807.2.2 FBC1807.3.3 |
| | PROVIDE INFORMATION ON PLAN FOR SLAB ELEVATION AT BASE |
| | OF SHAFT AND WATERPROOFING OF WALLS AND SLAB |
| | |
| | |
| | 3. FBC -3006.1 ELECTRICAL ROOM |
| | CAN?T HAVE AN ELECTRICAL ROOM LOCATED IN A TENANT |
| | SPACE |
| | |
| | 11-4.6.4SINAGEHANDICAP SIGN |
| | PROVIDE THE DETAIL OF HANDICAP SIGN WITH HEIGHT, |
| | REQUIRED INFORMATION ON SIGN, SYMBOL |
| | |
| | DOOR SCHEDULE |
| | IDENTIFY THE DOORS ON THE FLOOR PLAN AS DESCRIBED ON |
| | DOOR SCHEDULE |
| | |
| | FBC-11-4.4.2 FIGURE8-C-1 HEADROOM |
| | A-7.2A-7.3VERIFY HEADROOM FIRST FLOOR TO LANDING |
| | |
| | FBC ? 11-7.2COUNTER ACCESSIBILITY |
| | (1)36?MAX HEIGHT COUNTER |
| | (2)FOLDING SHELF |
| | |
| | FBC-11-4.13.5ROOM 219 |
| | CLEAR WIDTH ON LATCH SIDE OF DOOR IN OUT-SWING |
| | POSITION REQUIRES 18? |
| | |
| | FBC-11-4.1.3(11)ALL TOILET ROOMS SHALL BE |
| | ADAPTABLE |
| | THIS MEANS THE TOILET ROOMS SHALL REQUIRE THE CORRECT |
| | WIDTH AND REQUIRED BACKING FOR HANDICAP |
| | FIXTURES SHOULD THEY BE NEEDED IN THE FUTURE. |
| | |
| | FBC-1210.2RESTROOMS |
| | GYPSUM BOARD MUST BE NON-ABSORBENT, NOTE ON PLANS |
| | |
| | FBC-11-4.23, 11-4.24-7ACCESSIBILITY |
| | LUNCH ROOM SPACE 240NEEDS CLEAR FLOOR SPACE UNDER |
| | SINKS FOR FORWARD APPROACH |
| | |
| | FBC-1609 GENERATOR |
| | SUBMIT SPECIFICATIONS, FASTENING TO SLAB FOR MOMENT OF |
| | OVERTURNING |
| | |
| | FBC- 1406.2.2EIF?S |
| | ARCHITECTURAL TRIM OVER 40 FEET IN HEIGHT |
| | A-5.1 CANNOT BE COMBUSTIBLE |
| | |
| | STRUCTURAL SHEET1-5.2 |
| | PROVIDE SECTION THROUGH GUARD RAIL (RAILING) DETAIL |
| | 1-2-3 |
| | |
| | STRUCTURAL SHEETWINDOW JAMBS |
| | IDENTIFY DOWELS IN MASONRY UNITS |
| | |
| | ARCHITECTURAL SHEETA-10.0BALCONY |
| | REQUIRES SECOND DRAIN |
| | |
| | TRUSSES-TRUSS REPORT |
| | LATERAL LOADS NOT IN COMPLIANCE,CHECK CHART WITH |
| | SIMPSON@ WWW.STRONGTIE.COM |
| | |
| | |