| Plan Review Notes For Permit 07070269 |
| Permit Number |
07070269 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-09-06 11:49:49 | *****DENIED***** | | | | | | | | | 1.NFPA 101, LIFE SAFETY CODE, 2003 EDITION SHALL BE | | | REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.SPECIFY WALL RATING BETWEEN GARAGE AND LIVING | | | AREA. | | | | | | 4.ON SHEET A-5, AMEND VERBAGE TO READ SMOKE ALARMS | | | (SA) INSTEAD OF SMOKE DETECTORS (SD).BE ADVISED THAT | | | SMOKE DETECTORS ARE TIED INTO A FIRE ALARM SYSTEM FOR | | | THE BUILDING, WHEREAS SMOKE ALARMS ALERT THE | | | OCCUPANT(S) OF THE DWELLING UNIT. | | | | | | 5.ON SHEET A-7 INCLUDE THE APPROPIATE DIRECTION WITH | | | THE FRONT, REAR, LEFT SIDE, AND RIGHT SIDE EXTERIOR | | | ELEVATIONS FOR CORRELATION. | | | | | | 6.ON THE APPROPIATE EXTERIOR ELEVATION FRONTING LILAC | | | COURT, POST THE NUMERICAL ADDRESS ON THE BUILDING.AS | | | PER WEST PALM BEACH CODE, THOSE NUMBERS (515) SHALL BE | | | NO LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN WIDTH. | | | THE UNIT CHARACTERS (NUMBERS OR LETTERS) SHALL BE NO | | | LESS THAN 3" IN HEIGHT AND NO LESS THAN 1" IN WIDTH. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | | ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|