| 2007-10-04 18:59:11 | PROJECT: 1801 SOUTH FLAGLER DRIVE, SUITE |
| | 1903/#07070044 |
| | |
| | PROJECT DETAILS: INTERIOR DEMOLITION/ALTERATION |
| | |
| | CODE REVIEW: 2004 FLORIDA BUILDING CODE/EXISTING |
| | BUILDING CODE WITH 2006 REVISIONS. |
| | |
| | STATUS: DENIED |
| | |
| | |
| | COMMENTS: |
| | |
| | (X) = COMPLIED |
| | |
| | |
| | 1) PRIOR TO RE-SUBMITTING THE REVIEWED PLANS, PLEASE |
| | MAKE CERTAIN TO REVIEW AND ADDRESS EACH COMMENT AS |
| | NOTED BELOW AND MAKE ALL CORRECTIONS WHERE APPLICABLE. |
| | FAILURE TO DO SO WILL IMPEDE THE EXPEDITING OF THE |
| | PERMIT ISSUANCE. |
| | |
| | 2)NEED TO FILE A NOTICE OF COMMENCEMENT, PER F. S. |
| | 713.13 . |
| | |
| | (X) 3)301.5 . A DESIGN PROFESSIONAL OR AN OWNER MUST |
| | ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION |
| | PURSUANT TO SECTION |
| | 303,304 & 305 OF THIS CODE. |
| | |
| | (X) 4) AS PER THE FBC 106.3.5, PLEASE PROVIDE THE |
| | FOLLOWING DATA: |
| | |
| | A) BUILDING CONSTRUCTION TYPE |
| | B) SPRINKLERED OR NON-SPRINKLERED. |
| | |
| | (X) 5)PLEASE CONTACT ALEX ORTEGA AT 561.355.3023 EXT. |
| | 1148, AS PER THE FOLLOWING: |
| | |
| | 105.9 ASBESTOS. |
| | |
| | THE ENFORCING AGENCY SHALL REQUIRE EACH BUILDING PERMIT |
| | FOR THE DEMOLITION OR RENOVATION OF AN EXISTING |
| | STRUCTURE TO CONTAIN AN ASBESTOS NOTIFICATION STATEMENT |
| | WHICH INDICATES THE OWNER'S OR OPERATOR'S |
| | RESPONSIBILITY TO COMPLY WITH THE PROVISIONS OF SECTION |
| | 469.003, FLORIDA STATUTES, AND TO NOTIFY THE DEPARTMENT |
| | OF ENVIRONMENTAL PROTECTION OF HIS OR HER INTENTIONS TO |
| | REMOVE ASBESTOS, WHEN APPLICABLE, IN ACCORDANCE WITH |
| | STATE AND FEDERAL LAW. |
| | |
| | 6) PLEASE PROVIDE DEMOLITION PLAN. |
| | |
| | (X) 7) PLEASE PROVIDE A DOOR SCHEDULE. |
| | |
| | (X) 8) INDICATE WALL TYPES AND CLARIFY TYPICAL INTERIOR |
| | PARTITION DETAIL. THE DETAIL INDICATES A 1/2 PLYWOOD |
| | SUB-FLOOR OVER LIGHT WEIGHT. |
| | |
| | (X) 9) PLEASE INDICATE FINISHED FLOOR COVERINGS. |
| | |
| | (X) 10) PLEASE PROVIDE DETAILS FOR FLOOR/CEILING/WALL |
| | PENETRATION FIRE PROTECTION. |
| | |
| | 11) SUBMIT PRODUCT SPECIFICATIONS FOR TRANSLUCENT |
| | GLAZING. |
| | |
| | (X) 12) PLEASE INDICATE KITCHEN CLEARANCES AND COUNTER |
| | HEIGHTS. |
| | |
| | (X)13) PLEASE PROVIDE DETAILS FOR FLOATING GYPSUM BOARD |
| | CEILING. |
| | |
| | 14) SUBMIT PRODUCT SPECIFICATIONS FOR SANDSTONE |
| | PANELS/SHOW EXTERIOR WALL SECTION/MECHANICAL |
| | ATTACHMENT/FASTENER TYPES/GAGE OF S.S.ANGLES. |
| | |
| | 15) PLEASE INDICATE CEILING HEIGHTS AND INDICATE IF ALL |
| | EXISTING FLOORS ARE BUILT-UP. |
| | |
| | 16) PLEASE SHOW DETAIL OF ENTRY DOOR THRESHOLD AND HOW |
| | IT WILL COMPLY WITH THE FAIR HOUSING ACT. |
| | |
| | 17) THE SUBFLOOR IS SHOWN AS PLYWOOD. THE FOLLOWING |
| | SHALL APPLY: |
| | |
| | 717.5 COMBUSTIBLES IN CONCEALED SPACES IN TYPE I OR II |
| | CONSTRUCTION. |
| | COMBUSTIBLES SHALL NOT BE PERMITTED IN CONCEALED SPACES |
| | OF BUILDINGS OF TYPE I OR II CONSTRUCTION. |
| | EXCEPTIONS: |
| | 1. COMBUSTIBLE MATERIALS IN ACCORDANCE WITH SECTION |
| | 603. |
| | 2. COMBUSTIBLE MATERIALS COMPLYING WITH SECTION 602 OF |
| | THE FLORIDA BUILDING CODE, MECHANICAL. |
| | 3. CLASS A INTERIOR FINISH MATERIALS. |
| | 4. COMBUSTIBLE PIPING WITHIN PARTITIONS OR ENCLOSED |
| | SHAFTS INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF |
| | THIS CODE. COMBUSTIBLE PIPING SHALL BE PERMITTED WITHIN |
| | CONCEALED CEILING SPACES WHERE INSTALLED IN ACCORDANCE |
| | WITH THE FLORIDA BUILDING CODE, MECHANICAL AND THE |
| | FLORIDA BUILDING CODE, PLUMBING. |
| | |
| | |
| | |