Text |
| 2007-10-19 15:33:58 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | 1.PLANS ARE TO SHOW CODE COMPLIANCE.THE RESPONSE |
| | LETTER CAN BE HELPFUL IN EXPLAINING HOW A COMMENT WAS |
| | ADDRESSED. BUT THE PLANS SHOULD CLEARLY SHOW SCOPE OF |
| | WORK. |
| | |
| | 2.THE RESPONSE LETTER GIVES INFORMATION WHICH IS |
| | DESIGN RELATED.ONLY CODE COMPLIANCE IS ADDRESSED IN |
| | THE PLAN REVIEW.IT APPEARS THAT YOU ARE CLOSING AN |
| | EXISTING OPENING AND CREATING A NEW ONE.THIS NEEDS TO |
| | BE SHOWN ON THE PLAN, USING THE FLOOR PLAN, DETAILS, |
| | AND DETAIL MARKERS. |
| | |
| | 3.PROVIDE A DETAIL FOR THE INFILL AND A DETAIL FOR |
| | THE FRAMING OF THE NEW OPENING.STATING THAT YOU ARE |
| | INSTALLING 4 STUDS IS NOT SUFFICIENT NOR CODE |
| | COMPLIANT. |
| | |
| | 4.ON THE INSTALLATION SCHEDULE, STATE WHICH |
| | CONNECTION TYPE YOU ARE USING.YOU'VE CIRCLED ALL OF |
| | THEM ON THE PRODUCT APPROVAL.THE 6" SPACING WHICH YOU |
| | SPECIFY IS NOT COMPLIANT FOR ALL CONNECTION MOUNTING |
| | TYPES.THIS SHOULD BE A THROUGH L, SEE SHEETS 13-15. |
| | |
| | 5.A 2" EDGE DISTANCE REQUIRES A FACTOR OF .5, SEE |
| | SHEET 14 OF THE PRODUCT APPROVAL.INFORMATIONAL; |
| | AFFECTS ANCHOR SPACING, CANNOT BE REVIEWED AS |
| | CONNECTION MOUNTING TYPE HAS NOT BEEN SPECIFIED. |
| | |
| | 6.SPANS SHOULD EQUAL BLADE LENGTH, SO SHOULD |
| | CORRELATE WITH THE OPENING HEIGHT.REVISE INSTALLATION |
| | SCHEDULE. |
| | |
| | 7.THE FIRST COMMENT LISTS REQUESTED THAT THE PLANS |
| | SHOW HOW EMERGENCY EGRESS FOR BEDROOMS WILL BE |
| | ADDRESSED.IT IS NOT CLEAR HOW THIS HAS BEEN |
| | ADDRESSED, FBC 310, FBC EB505.1. |
| | |
| | 8.ANOTHER COMMENT LIST HAD REQUESTED THAT THE |
| | APPLICATION BE REVISED TO REFLECT SCOPE OF WORK (AFTER |
| | CONTRACTOR STATED THAT ONLY S/H WINDOWS WERE BEING |
| | INSTALLED).IT STILL STATES "DUAL ACTION AND SINGLE |
| | HUNG".PLANS ARE TO SHOW WHICH WINDOW TYPE WILL BE |
| | INSTALLED IN EACH LOCATION.REVISE APPLICATION IF ONLY |
| | ONE WINDOW TYPE IS BEING INSTALLED. |
| | |