| Date |
Text |
| 2007-07-30 09:28:56 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC |
| | FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | 1.)TWO COLLATED IDENTICAL SETS REQUIRED FOR |
| | PERMITTING.ONLY ONE INSTALLATION SCHEDULE WAS |
| | SUBMITTED. |
| | |
| | 2.)SEE SHEET 8 OF THE PANEL PRODUCT APPROVAL.EDGE |
| | DISTANCE OF 3" REQUIRES A FACTOR OF .86 FOR ANCHOR |
| | SPACING. |
| | |
| | 3.)ANCHOR TYPE "316 AISI" IS NOT CONSISTENT WITH THE |
| | ANCHORS ON THE PRODUCT APPROVAL.THIS SHOULD CORRELATE |
| | WITH ANCHORS ON THE ANCHOR SPACING CHART (CALK-IN, |
| | SOLID SET, PANEL MATE, ETC.).NOTE THAT YOU HAVE |
| | SPECIFIED "TAPCON" FOR THE ACCORDIONS, BUT HIGHLIGHTED |
| | SPACING FOR SOLID SET. |
| | |
| | 4.)PLEASE MARK DETAILS IN INK RATHER THAN HIGHLIGHTER |
| | ON THE PRODUCT APPROVAL AS THE HIGHLIGHTER DOES NOT |
| | APPEAR WHEN SCANNED.THIS IS NOT REQUIRED FOR |
| | PERMITTING (AS ALL INFORMATION WILL BE INCLUDED ON THE |
| | INSTALLATION SCHEDULE) BUT DOES HELP TO EXPEDITE PLAN |
| | REVIEW. |
| | |
| | 5.)WHEN YOU SPECIFY A CBS SUBSTRATE, YOU MUST USE THE |
| | "TO MASONRY" OR "CONCRETE BLOCK" COLUMN, NOT "TO |
| | CONCRETE" OR "POURED CONCRETE". |
| | |
| | 6.)A DESIGN PRESSURE OF -44.8 REQUIRES USE OF THE -60 |
| | COLUMN, NOT -40. |
| | |
| | 7.)THE SHUTTER MOUNTING CONNECTION TYPE SHOULD STATE |
| | WHICH CONECTION TYPE YOU ARE USING, NOT THE ANCHOR. FOR |
| | THE PANELS, THIS WILL BE 1-9; FOR THE ACCORDIONS IT |
| | WILL BE A THROUGH L. |
| | |
| | 8.)SHUTTER MOUNTING CONNECTION TYPES A AND D WERE |
| | HIGHLIGHTED.NOTE THAT THESE CONNECTION TYPES REQUIRE |
| | A POURED CONCRETE SUBSTRATE, NOT BLOCK. |
| | |
| | 9.)1" IS NOT ADEQUATE FOR THE MINIMUM GLASS |
| | SEPARATION FOR ACCORDIONS, SEE SHEET 12. |