| 2007-07-14 11:51:06 | |
| | |
| | DENIED |
| | |
| | 1)CONTRACTORS SIGNATURE WAS NOT WITNESSED AND |
| | NOTARIZED ON PERMIT APPLICATION |
| | |
| | 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | NOTE: FEES ARE DUE IN THE AMOUNT OF $ 378.26 FOR |
| | INCREASED VALUE AND STATE RADON FEES THIS AMOUNT IS |
| | REQUIRED TO BE PAID PRIOR TO FURTHER PLAN REVIEW |
| | |
| | 4)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SETS OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561) 233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 5)THE 2006 AMENDMENTS TO THE 2004 FBC REQUIRE |
| | BUILDINGS LOCATED WITHIN EXP B TYPE TERRAIN THAT IS |
| | DIRECTLY ADJACENT TO EXP C TYPE TERRAIN SUCH AS OPEN |
| | GOLF COURSES AND BODIES OF WATER FOR A DISTANCE OF 600 |
| | FEET OR MORE IN ANY QUADRANT TO BE IN AN EXP C |
| | CATEGORY. PLEASE ADJUST THE DESIGN PARAMETERS AND WIND |
| | PRESSURES ACCORDINGLY |
| | |
| | 6)PROVIDE THE DESIGN PRESSURE VALUES FOR THE NEW |
| | WINDOW OPENINGS |
| | |
| | |
| | |
| | 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL COVER |
| | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| | SUBMITTED APPLICATIONS WILL BE DENIED |
| | |
| | 8)SUBMIT ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT |
| | APPLICATION OR BEFORE INSTALLATION THAT |
| | HAVE BEEN REVIEWED AND APPROVED BY THE |
| | DESIGNER OF RECORD |
| | |
| | 9)SUBMIT ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND |
| | DATED BY PREPARER AND OWNER/AGENT PRIOR |
| | TO SUBMITTAL. NOTE THE ENERGY CALC'S ARE NOT SIGNED BY |
| | OWNER/AGENT AND INFORMATION ON WALL R VALUE IS MISSING |
| | |
| | 10)DRAWINGS ARE TO CONTAIN THE INSULATION VALUES TO |
| | MATCH THE ENERGY CALC'S. PLEASE NOTE THAT ENERGY CALC |
| | HAS R VALUE FOR RAISED FLOOR BUT DRAWING DOES NOT SHOW |
| | ANY INSULATION AT ALL |
| | |
| | 11)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER |
| | R313.1.1 FBC RES. |
| | |
| | 12)ADDITIONAL PERMITS WILL BE REQUIRED FOR |
| | ELECTRICAL, FIRE SPRINKLERS AND ROOFING |
| | |
| | 13)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED |
| | |
| | NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006 |
| | AMENDMENTS |
| | FBC* = WEST PALM BEACH ADMINISTRATIVE |
| | AMENDMENTS TO FBC |
| | FAC = FLORIDA ADMINISTRATIVE CODE |
| | FS = FLORIDA STATUTES |
| | FBC RES. = FLORIDA BUILDING CODE |
| | RESIDENTIAL 2004 W/2006 AMENDMENTS |
| | |
| | BLDG PLAN REVIEW |