| 2007-10-02 18:57:59 | |
| | |
| | DENIED |
| | |
| | THE FOLLOWING COMMENTS WERE NOT ADDRESSED FROM 1ST |
| | REVIEW ON 7/14/07: |
| | |
| | 5)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND DATED BY PREPARER |
| | AND OWNER/AGENT PRIOR TO SUBMITTAL |
| | ****NOTE MAKE THE FOLLWING CORRECTIONS TO ENERGY |
| | CALC'S, WALLS ARE WOOD FRAME NOT CONCRETE, THEY ARE NOT |
| | SIGNED BY OWNER AGENT, AND UNLESS COMPLETE HOUSE IS |
| | BEING BROUGHT UP TO NEW ENERGY STANDARDS FORM 600C-04R |
| | SHOULD BE USED FOR ADDITIONS OR RENOVATIONS 600 SQ. FT. |
| | OR LESS**** |
| | |
| | 7)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL |
| | COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006 |
| | AMENDMENTS PER 106.1.1 FBC* |
| | ****NOTE THIS SHALL BE INCUDED ON THE PERMIT SET OF |
| | DRAWINGS**** |
| | |
| | 8)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING |
| | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF |
| | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND |
| | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE |
| | DRAWINGS |
| | ****NOTE ALTERATION LEVEL FITS THE DEFINITION OF A |
| | LEVEL 2, PLEASE SEE ATTACHED COPY OF CHAPTER 3 |
| | CLASSIFICATION OF WORK**** |
| | |
| | NEW COMMENTS |
| | |
| | 1)PROVIDE PRODUCT APPROVALS FOR THE NEW FRONT ENTRY |
| | DOOR |
| | |
| | 2)NEW NOTE UNDER WINDOW SCHEDULE ON A-3 IS INCORRECT |
| | PLEASE REMOVE, ALL OPENINGS WITHIN 30 FEET OF GRADE |
| | SHALL MEET LARGE MISSILE IMPACT REQUIREMENTS PER |
| | 1609.1.4 (1) FBC |
| | |
| | 3)PROVIDE PRODUCT APPROVALS FOR SHUTTERS FOR WINDOWS |
| | IN NEW LOCATIONS |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |