Plan Review Notes
Plan Review Notes For Permit 07060850
Permit Number 07060850
Review Stop B
Sequence Number 3
Notes
Date Text
2008-02-12 13:39:032004 FBC W/2006 REVISIONS
  
 DENIED BY BUILDING
  
 1) THE NOTICE OF COMMENCEMENT WILL NEED TO BE RECORDED
 AND A COPY SUBMITTED.
  
 2) PLEASE CLARIFY IF THE ROOF-CEILING CONSTRUCTION IS
 CONVENTIONAL FRAMING OR SITE BUILT TRUSSES. IF THE ROOF
 IS CONVENTIONAL FRAMING, SUBMIT DETAILS SHOWING THE
 RAFTER, CEILING JOIST AND RIDGE SIZES AND CONNECTORS.
 THE CONVENTIONAL ROOF FRAMING IS REQUIRED TO COMPLY
 WITH THE IBHS GUIDELINE FOR HURRICANE RESISTANT
 CONSTRUCTION OR ASCE7-02.
 IF SITE BUILT-UP TRUSSES ARE USED, SUBMIT DETAILS FOR
 THE SITE BUILT UP-TRUSSES. PROVIDE DETAILS FOR EACH
 DIFFERENT TYPE OF TRUSS, SPECIFY THE LUMBER TYPE AND
 SIZES FOR THE TOP AND BOTTOM CORDS AND WEBS. SPECIFY
 HOW THE CORDS AND WEBS WILL BE CONNECTED TOGETHER.
 PROVIDE ENGINEERING OR CALCULATIONS INDICATING THAT THE
 TRUSSES ARE CAPABLE OFWITHSTANDING 140 MPH WINDLOADS.
 FBC R 802.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]