Plan Review Notes
Plan Review Notes For Permit 07060804
Permit Number 07060804
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-12 12:58:56BUILDING REVIEW CHECKLIST:
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED
 BY SEC. 713.13 FLORIDA STATUTE.
  
 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD
 (561)233-5115)TO PAY IMPACT FEES. BRING BACK STAMPED
 PLANS AND COPY OF PAID RECEIPT.
  
 3- REVISE ADDRESS ON ALL DRAWINGS. COORDINATE WITH
 LILLY AT(561)822-1239 FOR CORRECT ADDRESS.
  
 4- PROVIDE DRAINAGE PLAN AS REQUIRED BY SEC.R401.3 OF
 2004 FLORIDA RESIDENTIAL CODE.
 ***NOTE: MAKE SURE WATER IS DIVERTED AWAY FROM
 NEIGHBOR'S PROPERTY.
  
 5- VALUE DECLARED IN THE PERMIT APPLICATION WAS UPDATED
 AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004.
 OWES $68.04 FOR UPDATED VALUATION AND RADON FEES.
  
 6- PLANS TO SPECIFY BUILDING CONSTRUCTION TYPE AS
 REQUIRED BY SEC. 602.1 FBC 2004.
  
 7- SPECIFY THE DESIGN PRESSURES FOR ALL EXTERIOR
 OPENINGS AS REQUIRED BY SEC. R3012004 FLORIDA
 RESIDENTIAL CODE.
  
 8- SPECIFY ROOF SHEATHING NAIL TYPE AND SPACING
 ACCORDING TO THE ROOF ZONE. SEE SEC. R803.2.3.1 OF 2004
 FLORIDA RESIDENTIAL CODE FOR MINIMUM REQUIREMENTS.
  
 9- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) EXTERIOR ENTRY AND REAR DOORS. NOA 01-0828.08
 PROVIDED EXPIRED ON 06/20/2007.
  
 B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS.
 ***NOTE: PROVIDE ONLY THE COVER PAGE AND PAGE SHOWING
 THE SPECIFIED CONNECTOR.
  
 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
 ***NOTE: LETTER SUBMITTED FROM THE ENGINEER IS TOO OLD
 (SIGNED AND SEALED IN 01/31/06)AND THEREARE PRODUCT
 APPROVALSTHAT DON'T APPLY TO THIS JOB.
 ENGINEER TO APPROVE ACTUAL PRODUCT APPROVALINSTEAD OF
 LETTER TO AVOID DELAYS OR CONFLICTS WITH SPECIFIC
 PRODUCT APPROVAL SUBMITTED.
  
 11- STORM SHUTTERS:
 A) PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED SAMPLE. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 B) ON STORM SHUTTERS DRAWINGS MARK SPECIFIC MOUNTING
 CONDITIONS (EG:WALL MOUNTED) AND SPECIFIC ANCHOR TYPE
 AND SPACING TO BE USED ACCORDING TO THE DESIGN
 PRESSURES, EDGE DISTANCE, PANEL SPAN, CONNECTION TYPE
 AND STRUCTURE TO BE ATTACHED TO (CONCRETE BLOCK). SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 12- SURVEY SUBMITTED STATES THAT "THIS SURVEY IS NOT
 USED FOR CONSTRUCTION OR DESIGN PURPOSES". PROVIDE
 SURVEY THAT CAN BE USED FOR PERMITTING PURPOSES.
 SURVEY NEED TO HAVE ORIGINAL SIGNATURE, NOT COPY, AS
 REQUIRED BY CHAPTER 472 FLORIDA STATUTE.
  
 13- SOIL TEST REPORT TO HAVE ENGINEERING FIRM'S
 CERTIFICATE OF AUTHORIZATION NUMBER IN THE LETTERHEAD
 AS REQUIRED BY SEC. 61G15-23.002 OF FLORIDA
 ADMINISTRATIVE CODE.
  
 14- SHEET 2:
 A) PORCH FOOTING SIZE FOR CONCRETE COLUMN SHOWN ON
 FOUNDATION PLAN DOESN'T MATCH SIZE SHOWN ON PORCH
 SECTION. REVISE AS REQUIRED TO MATCH.
  
 B) TYPICAL FOOTING SIZE SHOWN ON FOUNDATION PLAN
 DOESN'T MATCH FOOTING SIZE SHOWN ON TYP. WALL SECTION.
 REVISE AS REQUIRED TO MATCH.
  
 15- SHEET T1:CONNECTOR SCHEDULESTATES THAT
 SENG-CHAI TAN IS THE ENGINEER WHO PRODUCED THIS
 CONNECTOR SCHEDULE. THEN, THIS ENGINEER NEEDS TO SIGN
 AND SEAL THIS DRAWING AS REQUIRED BY SEC. 471 FLORIDA
 STATUTE AND FLORIDA ADMINISTRATIVE CODE.
  
 16- SHEET D-1: PROVIDE ONLY THE DETAILS THAT APPLY TO
 THIS JOB TO EXPEDITE REVIEWAND AVOID DELAYS OR
 CONFLICTS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712