| 2007-07-12 12:58:56 | BUILDING REVIEW CHECKLIST: |
| | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED |
| | BY SEC. 713.13 FLORIDA STATUTE. |
| | |
| | 2- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD |
| | (561)233-5115)TO PAY IMPACT FEES. BRING BACK STAMPED |
| | PLANS AND COPY OF PAID RECEIPT. |
| | |
| | 3- REVISE ADDRESS ON ALL DRAWINGS. COORDINATE WITH |
| | LILLY AT(561)822-1239 FOR CORRECT ADDRESS. |
| | |
| | 4- PROVIDE DRAINAGE PLAN AS REQUIRED BY SEC.R401.3 OF |
| | 2004 FLORIDA RESIDENTIAL CODE. |
| | ***NOTE: MAKE SURE WATER IS DIVERTED AWAY FROM |
| | NEIGHBOR'S PROPERTY. |
| | |
| | 5- VALUE DECLARED IN THE PERMIT APPLICATION WAS UPDATED |
| | AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004. |
| | OWES $68.04 FOR UPDATED VALUATION AND RADON FEES. |
| | |
| | 6- PLANS TO SPECIFY BUILDING CONSTRUCTION TYPE AS |
| | REQUIRED BY SEC. 602.1 FBC 2004. |
| | |
| | 7- SPECIFY THE DESIGN PRESSURES FOR ALL EXTERIOR |
| | OPENINGS AS REQUIRED BY SEC. R3012004 FLORIDA |
| | RESIDENTIAL CODE. |
| | |
| | 8- SPECIFY ROOF SHEATHING NAIL TYPE AND SPACING |
| | ACCORDING TO THE ROOF ZONE. SEE SEC. R803.2.3.1 OF 2004 |
| | FLORIDA RESIDENTIAL CODE FOR MINIMUM REQUIREMENTS. |
| | |
| | 9- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE |
| | 9B-72 FOR: |
| | A) EXTERIOR ENTRY AND REAR DOORS. NOA 01-0828.08 |
| | PROVIDED EXPIRED ON 06/20/2007. |
| | |
| | B) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON |
| | PLANS. |
| | ***NOTE: PROVIDE ONLY THE COVER PAGE AND PAGE SHOWING |
| | THE SPECIFIED CONNECTOR. |
| | |
| | 10- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| | ***NOTE: LETTER SUBMITTED FROM THE ENGINEER IS TOO OLD |
| | (SIGNED AND SEALED IN 01/31/06)AND THEREARE PRODUCT |
| | APPROVALSTHAT DON'T APPLY TO THIS JOB. |
| | ENGINEER TO APPROVE ACTUAL PRODUCT APPROVALINSTEAD OF |
| | LETTER TO AVOID DELAYS OR CONFLICTS WITH SPECIFIC |
| | PRODUCT APPROVAL SUBMITTED. |
| | |
| | 11- STORM SHUTTERS: |
| | A) PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE |
| | ATTACHED SAMPLE. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| | 2004. |
| | |
| | B) ON STORM SHUTTERS DRAWINGS MARK SPECIFIC MOUNTING |
| | CONDITIONS (EG:WALL MOUNTED) AND SPECIFIC ANCHOR TYPE |
| | AND SPACING TO BE USED ACCORDING TO THE DESIGN |
| | PRESSURES, EDGE DISTANCE, PANEL SPAN, CONNECTION TYPE |
| | AND STRUCTURE TO BE ATTACHED TO (CONCRETE BLOCK). SEC. |
| | 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| | |
| | 12- SURVEY SUBMITTED STATES THAT "THIS SURVEY IS NOT |
| | USED FOR CONSTRUCTION OR DESIGN PURPOSES". PROVIDE |
| | SURVEY THAT CAN BE USED FOR PERMITTING PURPOSES. |
| | SURVEY NEED TO HAVE ORIGINAL SIGNATURE, NOT COPY, AS |
| | REQUIRED BY CHAPTER 472 FLORIDA STATUTE. |
| | |
| | 13- SOIL TEST REPORT TO HAVE ENGINEERING FIRM'S |
| | CERTIFICATE OF AUTHORIZATION NUMBER IN THE LETTERHEAD |
| | AS REQUIRED BY SEC. 61G15-23.002 OF FLORIDA |
| | ADMINISTRATIVE CODE. |
| | |
| | 14- SHEET 2: |
| | A) PORCH FOOTING SIZE FOR CONCRETE COLUMN SHOWN ON |
| | FOUNDATION PLAN DOESN'T MATCH SIZE SHOWN ON PORCH |
| | SECTION. REVISE AS REQUIRED TO MATCH. |
| | |
| | B) TYPICAL FOOTING SIZE SHOWN ON FOUNDATION PLAN |
| | DOESN'T MATCH FOOTING SIZE SHOWN ON TYP. WALL SECTION. |
| | REVISE AS REQUIRED TO MATCH. |
| | |
| | 15- SHEET T1:CONNECTOR SCHEDULESTATES THAT |
| | SENG-CHAI TAN IS THE ENGINEER WHO PRODUCED THIS |
| | CONNECTOR SCHEDULE. THEN, THIS ENGINEER NEEDS TO SIGN |
| | AND SEAL THIS DRAWING AS REQUIRED BY SEC. 471 FLORIDA |
| | STATUTE AND FLORIDA ADMINISTRATIVE CODE. |
| | |
| | 16- SHEET D-1: PROVIDE ONLY THE DETAILS THAT APPLY TO |
| | THIS JOB TO EXPEDITE REVIEWAND AVOID DELAYS OR |
| | CONFLICTS. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |
| | (561)805-6712 |