| Plan Review Notes For Permit 07060741 |
| Permit Number |
07060741 |
|
| Review Stop |
M |
| Sequence Number |
4 |
|
| Notes |
| Date |
Text |
| 2007-09-14 09:45:41 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA | | | ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS). | | | | | | *** DENIED *** | | | 1) THE KITCHEN HOOD VENT IS GOING TO THE KITCHEN SINK, | | | PLEASE CORRECT. | | | | | | 2) SHOW SUPPLY AIR CFM'S AT ALL SUPPLY AIR GRILLS (SEE | | | YELLOW HIGH LIGHT ON MECHANICAL PLAN). | | | | | | 3) SHOW CFM'S AT BATHROOM EXHAUST FANS, SEE RES. | | | M1506.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|