| Date |
Text |
| 2007-08-16 14:33:30 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: |
| | |
| | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). |
| | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR |
| | NOI. |
| | YOU CAN GET NOI INFO FROM |
| | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ |
| | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), |
| | EFFECTIVE MAY 1, 2003 |
| | 2. PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & |
| | ITS ENCLOSURE PER CITY OF WPB, LOCATION MUST BE |
| | ACCESSIBLE FOR PICKUP TRUCK. |
| | 3. PLEASE SHOW IN YOUR CALCULATION HOW DID YOU |
| | DETERMINR FIRST FLOOR ELEVATION, PARKING LOT ELEVATION |
| | USING CENTER LINE OF ROAD , SIDEWALK ELEVATION, FLOOD |
| | ZONE AREA OF THIS SITE, & 5,10, 25, 100 YEAR FLOOD |
| | CRITERIATO DETERMINE THE FIRST FLOOR ELEVATION. |
| | PLEASE PROVIDE CALCULATIONS. |
| | 4. PLEASESHOW ON DRAWING THE TOTAL SITE AREA, |
| | PERVIOUS AREA, IMPERVIOUS AREA, LAKE AREA, GREEN AREA, |
| | PARKING/SIDEWALK AREA, BUILDING AREA ETC.ALSO PROVIDE |
| | WATER QUALITY CALCULATIONS FOR THIS SITE |
| | 4. MAKE SURE THESE SITE AREAS SHOWN ON DRAWINGS MUST |
| | MATCH WITH AREAS USED IN STORM WATER QUALITY |
| | CALCULATIONS. |
| | 5. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES |
| | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM |
| | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL |
| | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, ETC ON DRAWINGS, FROM YOUR CALCULATIONS.DO |
| | YOU HAVE EXFILTRATION TRENCHES? . PLEASE SHOW DRY |
| | DETENTION/WET DETENTION AREAS IN YOUR CALS. |
| | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST AROUND |
| | YOUR SITE EVENTHOUGH THEY ARE NOT IN YOUR SITE. |
| | 7. PLEASE PROVIDE A COPY OF SFWMD OR NPBID PERMIT,, A |
| | COPY OF GEO-TECH REPORT AND A LATESTEST COPY OF STORM |
| | STORM WATER QUALITY CALCULATIONS THAT YOU PROVIDED AT |
| | 45TH STREET. |
| | 8. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | SILT FENCE AROUND THE WHOLE SITE & CATCH BASINS NOT |
| | PARTIALLY OPEN.HEIGHT OF FENCE SHOULD BE HIGH ENOUGH |
| | PER FDEP TO STOP DUST & PARTICLES. |
| | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |