| Date |
Text |
| 2007-11-01 14:20:38 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: |
| | |
| | 1.PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & |
| | ITS ENCLOSURE AND THEIR DETAILSPER CITY OF WPB, |
| | LOCATION MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | PERYOUR RESPONSE OF 8/8/07, SITE PLAN SHEET 1.1 OR |
| | 2 OF 9 DO NOT SHOW NEITHER LOCATION NOR DETAILS OF |
| | DUMPSTER. |
| | 2.MAKE SURE THESE SITE AREAS SHOWN ON DRAWINGS MUST |
| | MATCH WITH AREAS USED IN STORM WATER QUALITY |
| | CALCULATIONS. |
| | YOURRESPONSE OF 8/8/07WAS: "THE SITE AREAS |
| | .....ARE CORRECT...." .OUR RESPONSE TO YOU:INFACT |
| | AREA SHOWN ON SITE PLAN SHEET 1.1NOT CONSISTENT WITH |
| | POST DEVELOPMENT SITE AREAS SHOWN ON SHEET 1 OF 2.FOR |
| | EXAMPLE ON SITE PLAN SHEET 1.1 TOTAL AREA 75503 SQ FT, |
| | AND PERVIOUS AREA 5616 SQ FT WHILEYOU HAVE SHOWN ON |
| | CALCULATION SHEET 1 OF 2TOTAL SITE AREA 17189 SQ FT |
| | AND PERVIOUS AREA 6870 SQ FTAND SO FORTH INCONSISTENT |
| | IN IMPERVIOUS AREA ALSO. |
| | 3. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER CATCH |
| | BASINS DRAINS AROUND YOUR SITE |
| | 4.THESTORM STORM WATER QUALITY CALCULATIONS MUST BE |
| | APPROVED FROM 1000 45TH STREET, ENGINEERING,BEFORE WE |
| | ISSUE A PERMIT. |
| | 5. PER CITY ORDINANCE NO. 4060-07,PLEASE SHOW ON |
| | DRAWINGS THE POLLUTION PREVENTION SILT AROUND THE SITE |
| | & CATCH BASINS DURING CONSTRUCTION AND DURING ALL |
| | DEMOLITION.HEIGHT OF FENCE SHOULD BE HIGH ENOUGH PER |
| | FDEP TO STOP DUST & PARTICLES. |
| | 6. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE ISSUE A |
| | PERMIT. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |