Plan Review Notes For Permit 07060304
Permit Number 07060304
Review Stop FIRE
Sequence Number 2
Notes
Date Text
2007-08-27 13:15:16*****UNSAT*****
 THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN
 CLEAR, CONCISE, AND CONSISTENT PLANS HAVE BEEN
 SUBMITTED.
  
  
 01.NFPA 101, THE LIFE SAFETY CODE, 2003 EDITION SHALL
 BE REFERENCED.
  
 02.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS
 SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT
 OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 04.THE REMOVAL AND/OR THE STOCKING OF NEW BUILDING
 MATERIALS & SUPPLIES SHALL NOT INTERFERE OR HINDER WITH
 EMERGENCY RESPONSE ACCESS TO THE PROPERTY OR VICINITY
 THEREOF (INCLUDING STREETS, ROADS, FIRE LANES).
  
 05.INDICATE IF THE EXISTING BUILDING OR PORTION
 THEREOF REPRESENTS A CHANGE OF OCCUPANCY TO A BUSINESS
 OCCUPANCY.IF SO, THE LIFE SAFETY REQUIREMENTS FOR A
 NEW BUSINESS OCCUPANCY SHALL APPLY.
  
 06.PLEASE PROVIDE THE OCCUPANT LOAD AS IN THE NUMBER
 OF PERSONS FOR WHOM MEANS OF EGRESS AND OTHER
 PROVISIONS ARE REQUIRED.
  
 07.DOORS COMPLYING WITH NFPA 101, 7.2.1 SHALL BE
 PERMITTED.
  
 08.PLEASE PROVIDE TRAVEL DISTANCE TO EXIT(S).
  
 09.INDICATE THE LOCATION OF EXIT LIGHTS, EMERGENCY
 LIGHTS, AND FIRE EXTINGUISHER(S).
  
 10.INTERIOR WALL AND CEILING FINISH MATERIAL SHALL BE
 CLASS A OR CLASS B IN EXITS AND IN EXIT ACCESS
 CORRIDORS, CLASS A, CLASS B, OR CLASS C IN ALL OTHER
 AREAS.BE SPECIFIC
  
 11.SEPARATE PLANS AND PERMIT SHALL BE PROVIDED IF THE
 FIRE SPRINKLER OR FIRE ALARM IS MODIFIED AS A RESULT OF
 THE SCOPE OF WORK.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE (ON THE PLANS) EACH ITEM WAS
 ADDRESSED
  
  