Plan Review Notes
Plan Review Notes For Permit 07060170
Permit Number 07060170
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-24 16:20:43 
  
 DENIED
  
 1)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME,
 ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS
 THEIR SEAL PER 61G15-23.002(2) FAC
  
 2)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*PLEASE NOTE THAT TITLE
 BLOCK INCORRECTLY LISTS 2003 FBC
  
 3)CONSTRUCTION DOCUMENTS SHALL INDICATE THE
 LOCATION/ADDRESS OF THE WORK ALONG WITH A CLEAR
 DEFINITION OF THE PROPOSED WORK. PLEASE NOTE THAT THE
 DRAWING SHALL INDICATE WHICH OF THE MANY SIGN TYPES AND
 SPECIFICATIONS ARE RELEVANT TO THE PERMITTED WORK.
  
 4)CLARIFY THE DISCREPANCY BETWEEN THE SPECIAL PURPOSE
 SURVEY AND THE SPECIFICATIONS/DRAWINGS. DETAIL "A"
 SHOWS SITE POLE OVERALL HEIGHT AT 80'-0" WHICH WOULD
 REQUIRE A 66" X .688" DIAMETER POLE BUT THE SURVEY
 SHOWS A 60" DIAMETER (5'-0") POLE
  
 5)PROVIDE INDEX SHEET WITH THE SPECIFICATIONS THAT
 OUTLINE THE ENGINEERING PAGES THAT APPLY TO THE
 SPECIFIC JOB (IE. COLUMN DESIGN PG. 49, AUGER
 FOUNDATION CALCULATIONS PG. 53 COLUMN #5, ETC.)
  
 6)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 NOTE: FBC = FLORIDA BUILDING CODE 2004 W/2006
 AMENDMENTS
 FBC* = WEST PALM BEACH ADMINISTRATIVE
 AMENDMENTS TO FBC
 FAC = FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
 FBC RES. = FLORIDA BUILDING CODE
 RESIDENTIAL 2004 W/2006 AMENDMENTS
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved