Plan Review Notes
Plan Review Notes For Permit 07060061
Permit Number 07060061
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-26 17:15:13****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)PROVIDE ANCHORING INFORMATION TO COMPLY WITH
 FBC1609.1.3, FBC R301; STRUCTURAL MEMBERS AND SYSTEMS,
 AND COMPONENTS AND CLADDING IN A BUILDING OR STRUCTURE
 SHALL BE ANCHORED TO RESIST WIND-INDUCED OVERTURNING,
 UPLIFT AND SLIDING AND TO PROVIDE CONTINUOUS LOAD PATHS
 FOR THESE FORCES TO THE FOUNDATION.WHERE A PORTION OF
 THE RESISTANCE TO THESE FORCES IS PROVIDED BY DEAD
 LOAD, THE MINIMUM DEAD LOAD LIKELY TO BE IN PLACE
 DURING A DESIGN WIND EVENT SHALL BE USED.
  
 2.)DECLARE WIND DESIGN CRITERIA, FBC1603.1.4.
  
 3.)THE PLAN GIVES THE SLAB DIMENSION BUT NO OTHER
 INFORMATION.PROVIDE A PLAN FOR THE SLAB SHOWING ALL
 STRUCTURAL INFORMATION, AND STATE WHETHER THIS IS
 FORMED AND POURED OR IF THIS IS A PREFAB SLAB.PREFAB
 SLABS REQUIRE ENGINEERED CALCULATIONS TO SHOW HOW IT
 CAN RESIST THE WIND LOADS FBC R 301.
  
 4.)TWO IDENTICAL COLLATED SETS REQUIRED FOR
 PERMITTING.