| 2007-07-26 17:15:13 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 |
| | FAC FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | 1.)PROVIDE ANCHORING INFORMATION TO COMPLY WITH |
| | FBC1609.1.3, FBC R301; STRUCTURAL MEMBERS AND SYSTEMS, |
| | AND COMPONENTS AND CLADDING IN A BUILDING OR STRUCTURE |
| | SHALL BE ANCHORED TO RESIST WIND-INDUCED OVERTURNING, |
| | UPLIFT AND SLIDING AND TO PROVIDE CONTINUOUS LOAD PATHS |
| | FOR THESE FORCES TO THE FOUNDATION.WHERE A PORTION OF |
| | THE RESISTANCE TO THESE FORCES IS PROVIDED BY DEAD |
| | LOAD, THE MINIMUM DEAD LOAD LIKELY TO BE IN PLACE |
| | DURING A DESIGN WIND EVENT SHALL BE USED. |
| | |
| | 2.)DECLARE WIND DESIGN CRITERIA, FBC1603.1.4. |
| | |
| | 3.)THE PLAN GIVES THE SLAB DIMENSION BUT NO OTHER |
| | INFORMATION.PROVIDE A PLAN FOR THE SLAB SHOWING ALL |
| | STRUCTURAL INFORMATION, AND STATE WHETHER THIS IS |
| | FORMED AND POURED OR IF THIS IS A PREFAB SLAB.PREFAB |
| | SLABS REQUIRE ENGINEERED CALCULATIONS TO SHOW HOW IT |
| | CAN RESIST THE WIND LOADS FBC R 301. |
| | |
| | 4.)TWO IDENTICAL COLLATED SETS REQUIRED FOR |
| | PERMITTING. |