| Date |
Text |
| 2007-07-17 19:30:11 | BUILDING PLAN REVIEW |
| | PERMIT:07060046 |
| | ADD: 700 S ROSEMARY AVE# 200 |
| | CONT: ***PLAN REVIEW*** |
| | TEL: (561)820-0074 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) ONCE FILED AS A PERMIT APPLICATION WITH CONTRACTOR |
| | READY TO ISSUE:FL S S 713.13NOTICE OF COMMENCEMENT, |
| | TO BE FILED WITH THE CLERK OF THE COURT.NOTE: |
| | 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENT IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS |
| | AFTER THE RECORDING THEREOF, SUCH NOTICE IS NULL & |
| | VOID. NOTE: 713.13(6) THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 3) SHEET A1 INDICATES THE WRONG ADDITION OF THE CODE, |
| | PLEASE CORRECT TO: 2204 FBC BUILDING W/ 2006 REVISIONS |
| | AND 2004 EXISTING BUILDING CODE, PLEASE INDICATE TO |
| | WHAT LEVEL OF ALTERATIONS WILL BE ACCOMPLISHED UNDER |
| | THIS PERMIT. |
| | |
| | 4) PLANS HAVEN'T BEEN STAMPEDWITH CITY PLACE |
| | APPROVAL!! 106.1.2* ADDITIONAL INFORMATION REQUIRED. |
| | |
| | 5) PLEASE SEE TITLE BLOCK ** BAKER/ NESTOR**ARE |
| | MISSING THEIR CERTIFICATE OF AUTHORIZATION,481.219 |
| | F.S.CERTIFICATE OF AUTHORIZATION.THE TITLE BLOCK |
| | FOR ANY SHEET BEARING THE NAME OF AN ARCHITECT |
| | PRACTICING UNDER A FICTITIOUS NAME, A CORPORATION, OR A |
| | PARTNERSHIP, OFFERING ARCHITECTURAL SERVICES, SHALL |
| | INCLUDE THE CERTIFICATE OF AUTHORIZATION NUMBER.ADD |
| | THE NUMBER TO EACH SHEET. THIS MAY BE ADDED BY HAND. |
| | |
| | 6) SHEET A2 & A3 BOTH INICATEA 1 HR RATED WALL WHERE |
| | AS TABLE 302.3.2 INDICATES 2HR SEPERATION. WHAT TYPE OF |
| | OCCUPANCIES ARE ON EITHER SIDE OF THIS SPACE? |
| | |
| | 7) PLANS DO NOT PROVIDE FOR 2 ACCESSIBLE MEANS OF |
| | EGRESS: 11-4.3.10 EGRESS. ACCESSIBLE ROUTES SERVING ANY |
| | ACCESSIBLE SPACE OR ELEMENT SHALL ALSO SERVE AS A MEANS |
| | OF EGRESS FOR EMERGENCIES OR CONNECT TO AN ACCESSIBLE |
| | AREA OF RESCUE ASSISTANCE. |
| | |
| | 8) PLANS DO NOT INDICATE ANY EXIT LIGHTS NOR STAIR OR |
| | RAMP ILLUMINATION.1006.1 MEANS OF EGRESS ILLUMINATION. |
| | ILLUMINATION OF MEANS OF EGRESS SHALL BE PROVIDED IN |
| | ACCORDANCE WITH THIS SECTION FOR EVERY BUILDING AND |
| | STRUCTURE. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT |
| | ACCESS SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, |
| | CORRIDORS, RAMPS, ESCALATORS AND PASSAGEWAYS LEADING TO |
| | AN EXIT. FOR THE PURPOSES OF THIS REQUIREMENT, EXIT |
| | DISCHARGE SHALL INCLUDE ONLY DESIGNATED STAIRS, AISLES, |
| | CORRIDORS, RAMPS, ESCALATORS, WALKWAYS AND EXIT |
| | PASSAGEWAYS LEADING TO A PUBLIC WAY. |
| | |
| | 10) PLEASE PROVIDE THE FLAME SPREAD AND SMOKE |
| | DEVELOPMENT FOR WALL FINISHES AND CEILING, SEE 803.1. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | |
| | BUILDING PLAN REVIEW II |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |