| 2007-07-08 19:55:15 | |
| | |
| | DENIED |
| | |
| | 1)PROVIDE DESIGN PARAMETERS ON DRAWINGS THIS INCLUDES |
| | THE CODE CYCLE (2004 FBC W/ 2006 AMENDMENTS) AND THE |
| | TYPE OF CONSTRUCTION |
| | |
| | 2)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| | PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE, |
| | AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| | APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | 4)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| | EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE |
| | SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES, |
| | AND THE PRODUCT NOA THAT LISTS THE SYSTEM COMPONENTS/ |
| | FASTENER LIST PAGES, THE PAGES WITH THE CHOSEN |
| | ASSEMBLY/ SYSTEM TO BE USED AND THE GENERAL LIMITATIONS |
| | PAGE. ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG |
| | |
| | 5)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | |
| | 6)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL COVER SHEETS WHEN AVAILABLE. |
| | THEY CAN BE SEARCHED FOR ON WWW.FLORIDABUILDING.ORG. |
| | WHEN AVAILABLE AND NOT SUBMITTED APPLICATIONS WILL BE |
| | DENIED |
| | |
| | 7)PROVIDE 2 COPIES OF RECENT SURVEY THAT SHOWS ALL |
| | EXISTING AND PROPOSED WORK, COMPLETE WITH ALL FRONT, |
| | SIDE AND REAR SETBACKS FROM BUILDINGS AND EQUIPMENT. |
| | |
| | 8)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE |
| | OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2 |
| | COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER |
| | R401.4 |
| | |
| | 9)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN |
| | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 |
| | |
| | 10)SUBMIT ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT |
| | APPLICATION OR BEFORE INSTALLATION THAT |
| | HAVE BEEN REVIEWED AND APPROVED BY THE |
| | DESIGNER OF RECORD |
| | |
| | 11)PROVIDE THEVALUATION ON THE PERMIT APPLICATION. |
| | FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS AND |
| | SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST EXCLUDING |
| | LAND VALUE. OUR VALUATION REFERENCE IS ICC (BVD), |
| | MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES PER |
| | 108.3 FBC*. IF VALUE IS FOUND TO BE LOW ADJUSTMENTS |
| | WILL BE MADE AND FEES DUE. |
| | |
| | 12)SUBMIT ENERGY CALC'S PER 13-101.2.2 FBC. BE SURE |
| | THAT THEY ARE SIGNED AND DATED BY PREPARER AND |
| | OWNER/AGENT PRIOR TO SUBMITTAL |
| | |
| | 13)FOUNDATION PLAN SHALL CONTAIN NOTES FOR VAPOR |
| | BARRIER AND TERMITE SOIL TREATMENT PER R506.2.3 & R320 |
| | FBC RES. |
| | |
| | 14)PROVIDE NOTE AT ALL SHOWER DOORS TO MEET SAFETY |
| | GLAZING IN HAZARDOUS LOCATIONS PER R308.4 ALSO DOOR |
| | SCHEDULE ON A/3 SHOWS SHOWER DOORS AS 1 1/2" THICK AND |
| | THE WALK IN CLOSET AS 3/8" THICK |
| | |
| | 15)PROVIDE SMOKE ALARMS AT EACH LEVEL PER R313.1 FBC |
| | RES. |
| | |
| | 16)STAIR HANDRAIL/GUARDS SHALL NOT ALLOW THE PASSAGE |
| | OF A 4" SPHERE PER R312.2 FBC RES. |
| | |
| | 17)SECOND FLOOR LINTEL MARKS ARE NOT ASSIGNED IN |
| | BUILDINGS 1 & 2 ON SHEET A/10 |
| | |
| | 18)LINTEL SCHEDULE SHOWS ALL SIZES AS 8F24 YET |
| | SECTIONS SHOW A 8F16 PLEASE CLARIFY |
| | |
| | 19)SECOND FLOOR FRAMING PLAN ON A/10 DOES NOT |
| | DESIGNATE A BEAM SIZE |
| | |
| | 20)PROVIDECOMPLETE CONNECTOR SCHEDULE WITH THE |
| | FLORIDA STATEWIDE APPROVAL NUMBERS (THIS SAVES PRINTING |
| | OF ALL PRODUCT APPROVALS FOR EACH CONNECTOR) |
| | |
| | 21)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO A PERMIT BEING |
| | ISSUED |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |