2007-11-01 17:54:39DENIED
 REFERENCE: FBC-2004 W/2006 AMENDMENTS
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
  
 ****FROM PREVIOUS REVIEW:
  
 1. OK
 2. OK
  
 3. SHT A-4 BREAK ROOM SINK SHALL BE ACCESSIBLE. PLEASE
 SUBMIT A DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24
 & ALL SUBSECTIONS. SHOW AN ELEVATION FOR SINK. SECTION
 106.1.2.
 ****RESPONSE NOTED, BUT SHOW COMPLIANCE FOR THE
 FOLLOWING:
 A. 11-4.24.4 SINK DEPTH
 B. 11-4.24.5 CLEAR FLOOR SPACE - FORWARD APPROACH
 REQUIRED. NO CABINET DOORS ALLOWED
 C. 11-4.24.6 EXPOSED PIPES & SURFACES
 D. 11-4.24.7 FAUCETS
  
 4. SUBMIT A DETAIL FOR THE ACCESSIBLE DRINKING
 FOUNTAIN. SHOW COMPLIANCE WITH SECTION 11-4.15 WITH ALL
 SUBSECTIONS AS WELL AS SECTION 11-4.1.3(10)(A)
 PROVISIONS FOR THOSE WHO HAVE DIFFICULTY BENDING OR
 STOOPING.
 ****RESPONSE NOTED, NOT ADDRESSED
  
 5. OK
 6. OK
  
 7. SHT AM-7 SANITARY PLUMBING RISER & TYPICAL RISER DO
 NOT REFLECT THE FLOOR PLAN, NOR DO THEY MEET CODE
 REQUIREMENTS. NO BREAK ROOM SINK IS SHOWN ON RISERS,
 WATER CLOSETS AND LAVS ARE BACK TO BACK, DRINKING
 FOUNTAINS ARE NOT VENTED. (SEE RED LINE EXAMPLE IF
 PIPING IS GOING OUT THE SIDE OF THE BUILDING).
 ****RESPONSE NOTED, BUT THE DRINKING FOUNTAINS ARE NOT
 VENTED AS SHOWN. (SEE RED LINE CORRECTIONS).
  
 8. OK
  
 9. SUBMIT A WATER RISER DIAGRAM THAT REFLECTS THE FLOOR
 PLAN. SECTION 106.3.5.1.3(3)(8)(10)(13).
 ****RESPONSE NOTED, BUT THE DRINKING FOUNTAINS ARE NOT
 INDICATED ON THE RISER DIAGRAM.
  
 10. OK
 11. OK
  