| 2007-09-27 10:17:33 | |
| | |
| | |
| | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07051134 |
| | ADD: 7816 S. DIXIE HWY |
| | CONT: S GROUP INC. |
| | TEL: (561)688-2295 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW 2ND |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| | YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) OK |
| | 3) OK |
| | |
| | 4)SUBMIT A WALL TYPE DETAIL SHEET FOR EACH TYPE OF |
| | WALL TO BE CONSTRUCTED. |
| | *****HOWEVER***** |
| | ON SHEET A-4 THE WALL SCHEDULE NEEDS TO BE MORE |
| | SPECIFIC. DETAIL B SHOWS A METAL STUD WITH PRESSURE |
| | TREATED 2X6 BASE PLATES. HOW WILL THE METAL STUD BE |
| | CONNECTED TO THE 2X6 PLATES?IF THERE ARE THREE |
| | DIFFERENT SIZE WALLS, EACH ONE SHALL HAVE ITS OWN |
| | DETAIL. |
| | |
| | 5)OK |
| | |
| | 6)ON THE PRODUCT CIRCLE OR HI-LIGHT WHICH ITEM WILL |
| | BE USED. INDICATE THE SIZE OF EACH WINDOW OPENING TO BE |
| | USED FROM THE PRODUCT APPROVAL. SUBMIT THE PRODUCT |
| | APPROVAL FOR THE WINDOW MULLIONS. |
| | **NO RESPONSE NOT ADDRESSED** THE PRODUCT APPROVAL FOR |
| | THE DOUBLE METAL DOOR # (1) IS REQUIRED. |
| | **NEW** |
| | (A) THE WALL LAYOUT ON SHEET A-4 DOES NOT CORRESPOND |
| | WITH THE LAYOUT ON M SHEETS. THE LOCATIONS OF THE AHU |
| | ROOMS ARE IN DIFFERENT LOCATIONS ON DIFFERENT SEE |
| | SHEETS M1 AND M2. ON SHEET M1 AHU ROOM #1 AND #2 ARE |
| | SHOWN IN DIFFERENT LOCATIONS ON SHEET AE-8.THE |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED. FBC.106.1.1. |
| | |
| | (B)ON SHEET A-3 THE EXISTING FLOOR PLAN INDICATE THAT |
| | SOME WALLS WILL BE RE-BLOCK, HOWEVER, ON SHEET A-4 THE |
| | SAME WALLS ARE SHOWN BEING FRAMED WITH METAL STUDS OR |
| | WOOD. CLARIFY. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | (561)805-6726 |
| | [email protected]. |