2007-06-16 12:53:26BUILDING PLAN REVIEW
 PERMIT: 07051094
 ADD: 1901 S.FLAGLER DR
 CONT: PRETI CONSTRUCTION, INC
 TEL: (561)840-9949
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PROJECT WAS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
  
 3)INDICATE THE ALTERATION-LEVEL PER 2004 FLORIDA
 EXISTING BUILDING CODE CH.3
  
 4)INDICATE THE SLOPE /LENGTH AND WIDTH OF THE RAMP.
 11-4.8.2 SLOPE & RISE. THE LEAST
 POSSIBLE SLOPE SHALL BE USED FOR ANY
 RAMP. THE MAXIMUM SLOPE FOR A RAMP IN
 NEW CONSTRUCTION SHALL BE 1 TO 12. THE
 MAXIMUM RISE FOR RUN SHALL BE 30" (SEE
 FIGURE 16).11-4.8.3. CLEAR WIDTH. THE MINIMUM CLEAR
 WIDTH OF A RAMP SHALL BE 36".
 EXCEPTION: RAMPS THAT ARE PART OF A
 REQUIRED MEANS OF EGRESS SHALL NOT BE
 LESS THAN 44 INCHES WIDE.
  
 5)11-4.5.1 GROUND AND FLOOR SURFACES ALONG ACCESSIBLE
 ROUTES AND IN ACCESSIBLE ROOMS AND SPACES INCLUDING
 FLOORS, WALKS, RAMPS, STAIRS, AND CURB RAMPS, SHALL BE
 STABLE, FIRM, SLIPRESISTANT, AND SHALL COMPLY WITH
 SECTION 11-4.5 .
  
 6)THE HANDRAILS SHALL MEET THE REQUIREMENTS OF FBC.
 11-4.8.5
  
 7)11-4.24.1 SINKS REQUIRED TO BE ACCESSIBLE BY
 SECTION 11-4.1 SHALL COMPLY WITH SECTION 11-4.24 . SHOW
 CONPLIANCE.
  
 8)106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. PROVIDE TWO COPIES OF THE
 PRODUCT APPROVALS FOR THE 8 INCH LINTEL.
  
 9)ADDITIONAL STRUCTURAL INFORMATION IS REQUIRED FOR
 THE WALL SECTION WHERE THE SINGLE DOOR AND WALL WILL BE
 REMOVED. SHOW THE STRUCTURAL SUPPORT OF THE WALL. THE
 BUILDING OFFICIAL MAY REQUIRE DETAILS, COMPUTATIONS,
 STRESS DIAGRAMS, AND OTHER DATA NECESSARY TO DESCRIBE
 THE CONSTRUCTION OR INSTALLATION AND THE BASIS OF
 CALCULATIONS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER