| Plan Review Notes For Permit 07050872 |
| Permit Number |
07050872 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2008-01-22 15:08:14 | *****************PROVISO****************** | | | THE MAIN HOUSE NEW PANTRY PERFBC PLUMBING SECTION | | | *909.1 WET VENT PERMITTED. | | | ANY COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS | | | LOCATED ON THE SAME FLOOR LEVEL ARE PERMITTED TO BE | | | VENTED BY A WET VENT. THE WET VENT SHALL BE CONSIDERED | | | THE VENT FOR THE FIXTURES AND SHALL EXTEND FROM THE | | | CONNECTION OF THE DRY VENT ALONG THE DIRECTION OF THE | | | FLOW IN THE DRAIN PIPE TO THE MOST DOWNSTREAM FIXTURE | | | DRAIN CONNECTION TO THE HORIZONTAL BRANCH DRAIN. ONLY | | | THE FIXTURES WITHIN THE BATHROOM GROUPS SHALL CONNECT | | | TO THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY | | | ADDITIONAL FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE | | | WET VENT. | | | THE NEW SINK FOR THE PANTRY MUST DRAIN DOWNSTREAM OF | | | THE EXISTING BATHROOM IF BATHROOM IS WET VENTED. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] | | | | | | |
|