| Plan Review Notes For Permit 07050734 |
| Permit Number |
07050734 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2007-06-14 07:18:03 | BUILDING PLAN REVIEW | | | PERMIT:07050764 | | | ADD: 1701 S.FLAGLER DR. | | | CONT: DESIGNER ALUMINUM INC. | | | TEL: (561)586-0656 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | ____ 1) A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED, | | | FS713.13. | | | | | | _XX___2.PROVIDE BUILDING HEIGHT ON THE PLAN. | | | DESIGN PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED | | | TO BE DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE | | | DONE BY AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER | | | AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | | ORIGINALS FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | ____4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT. | | | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | _XX___6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS | | | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A | | | HIGHLIGHTER. | | | | | | _XX___7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | | R310. | | | | | | ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4 | | | ABOVE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | | | | |
|