| Date |
Text |
| 2007-07-06 14:43:40 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: |
| | |
| | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). |
| | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR |
| | NOI. |
| | YOU CAN GET NOI INFO FROM |
| | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ |
| | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), |
| | EFFECTIVE MAY 1, 2003 |
| | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE |
| | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , |
| | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, |
| | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST |
| | FLOOR ELEVATION, MUST MEET THESE MINIMUM REQUIREMENTS. |
| | PLEASE SHOW IN YOUR STORM WATER CALS. |
| | 4. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE |
| | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL |
| | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, |
| | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE |
| | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED |
| | IN STORM WATER QUALITY CALCULATIONS. |
| | 5. HOW DO YOU CONNECT TO THE STORM WATER PIPES IN YOUR |
| | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES |
| | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM |
| | WATER PIPES FROM ALL OTHER STORM WATER PIPES. PLEASE |
| | SHOW DETAIL OF THE CONTROL STRUCTURESWITH |
| | ELEVATIONS, NOTCHES, BLEEDING ELEVATION, ETC ON |
| | DRAWINGS, DO YOU HAVE EXFILTRATION TRENCHES. PLEASE |
| | SHOW DRY DETENTION/WET DETENTION AREAS WITH 100% FILL |
| | OF STORM WATER ELEVATION? |
| | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND |
| | YOUR SITE FOR STORM WATER DRAIN. |
| | 7. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, |
| | 8.IN YOUR STORM WATER QUALITY CALCULATIONS,IN4. |
| | TREATMENT VOLUME PAGE, NO OF ACRES USED ARE CONFUSING, |
| | FOR EXAMPLE 14.67 ACRE, HOW DID YOU CALCULATE, I HAVE A |
| | PROBLEMS IN ALL NO OF ACRES USED IN STORM WATER QUALITY |
| | CALS IN THAT PAGE. YOU DID NOT SAY HOW DID YOU FIND NO |
| | OF ACRES OR GAVE US FINAL # AC-FT WHICH IS NOT |
| | ACCEPTABLE. |
| | 9. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT |
| | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE |
| | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & |
| | PARTICLES. |
| | 10. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |