| Plan Review Notes For Permit 07050558 |
| Permit Number |
07050558 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2008-03-12 11:33:02 | ****************PROVISO**************** | | | 1) FBC-2004 SEC. 424.2.12.1, OR | | | FBCR-2004 SEC. R4101.12.1 PRESSURE | | | TESTS. PER MANUFACTURE RECOMMENDATIONS, | | | NO AIR TEST SHALL BE APPROVED FOR PVC | | | PIPE AND FITTINGS. | | | | | | 2) FBC-2004 SEC. 424.2.13.2, OR | | | FBCR-2004 SEC.R4101.13.2 JOINTS AND | | | CONNECTIONS, FBC PLMG SEC 605.21, PURPLE | | | PRIMER REQUIRED ON PVC PIPING. | | | | | | 3) FBC-2004 SEC. 424.2.14.4, OR | | | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, | | | ALL WATER HEATING EQUIPMENT SHALL BE | | | INSTALLED WITH FLANGES OR UNION | | | CONNECTIONS ADJACENT TO THE HEATER. | | | | | | 4) FBC-2004 SEC. 424.2.14, OR FBCR-2004 | | | SEC. R4101.15 GAS PIPING SHALL COMPLY | | | WITH FBC FUEL GAS.SEPARATE PLANS AND | | | PERMIT REQUIRED. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|