2007-06-28 17:02:36BUILDING REVIEW CHECKLIST:
 1- PROPERTY IS LOCATED IN FLOOD ZONE "B", NOT "C".
 REVISE ORIGINAL SURVEY AS REQUIRED.
  
 2- SPECIFY CONSTRUCTION TYPE AS REQUIRED BY SEC. 602.1
 FBC 2004.
  
 3- SHEET 1 OF 6:
 A) UPDATE ALL INFORMATION GIVEN IN THE WIND
 INFORMATION AT THE BOTTOM LEFT SIDE OF THE SHEET.SEE
 2006 REVISED SHEETS OF 2004 FLORIDA RESIDENTIAL CODE
 AND FBC 2004.REFERENCE CORRECT CODE SECTION AND
 TABLE.
  
 B) UPDATE DESIGN PRESSURES AT WINDOWS AND DOORS
 OPENINGS AND PROVIDE CORRECT REFERENCE TABLES. SEE
 REVISIONS TO 2004 FLORIDA RESIDENTIAL CODE AND FBC 2004
 AND REVISE ALL INFORMATION AS REQUIRED.
  
 4- SHEET 2 OF 6:
 A) SPECIFY SAFETY GLASS FOR WINDOW BY TUB AS
 REQUIRED BY SEC. R308.4 OF 2004 FLORIDA RESIDENTIAL
 CODE.
 *** NOTE: NO REQUIREDIF USING HURRICANE MISSILE
 IMPACT GLASS.
  
 B) SPECIFY HOW IS EXISTING TIE BEAM REINFORCED TO
 RECEIVE THE PROPOSED ADDITIONAL LOAD AT AREAS WHERE THE
 BEARING WALL IS REMOVED. SEC. 106.1.2 CITY AMENDMENTS
 TO FBC 2004.
  
 5- SHEET 3 OF 6:
 A) LINTEL DESIGN LOADS DON'T MATCH INFORMATION GIVEN
 ON SHEET 1. REVISE AS REQUIRED.
  
 B) WHERE IS THE SITE ENGINEERING PLAN SPECIFIED IN
 THE FOUNDATION PLAN.
  
 C) CLARIFY WHY USING THE SAME LINTEL SIZE FOR ALL
 OPENINGS. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 D) INFORMATION SHOWN ON FOUNDATION PLAN AND DETAILS
 2 AND 5 DON'T MATCH. REVISE AS REQUIRED.
  
 6- SHEET 4 OF 6:
 A) UPDATE SIMPSON STRAP SCHEDULE. SEE CURRENT
 CATALOG AND REVISE AS REQUIRED. OTHERWISE, PROVIDE
 COMPLETE ENGINEERING ANALYSIS FOR NAIL SIZE AND NUMBER
 THAT DIFFER FROM THOSE TESTED AND PUBLISHED BY THE
 MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 B) CONNECTOR #1 CAN'T BE USED TO ATTACH TRUSS TO
 EXISTING BEAM.CONNECTOR NEEDS TO BE EMBEDDED. NEED TO
 SPECIFY WOOD TO MASONRY CONNECTOR THAT WORKS FOR
 PROPOSED APPLICATION. REVISE AS REQUIRED.
  
 7- SHEET 5 OF 6:
 A) UPDATE INFORMATION GIVEN ON THE GENERAL
 CONSTRUCTION NOTES.SEE CURRENT CODES AND REVISE AS
 REQUIRED.
  
 B) SPECIFY ROOF SHEATHING NAIL TYPE AND SPACING FOR
 ALL ROOF ZONE AREAS. SEE SEC. R803.2.3.1 OF 2004
 FLORIDA RESIDENTIAL CODE AND PROVIDE INFORMATION AS
 REQUIRED.
  
 C) PROVIDE DETAIL/SPECS FOR ROOF CROSS VENTILATION
 AS REQUIRED BY SEC. R806 OF 2004 FLORIDA RESIDENTIAL
 CODE.PROVIDE SPECIFIC SIZE AND LOCATION OF VENTS. ***
 NOTE: VENTS SHOWN ON TYP. WALL SECTION DON'T WORK.
 REVISE AS REQUIRED.
  
 D) ATTIC INSULATION SHOWN ON DETAILS AND INFORMATION
 SHOWN ON ENERGY CALCULATIONS DON'T MATCH. REVISE AS
 REQUIRED.
  
 E) PROVIDE COMPLETE AND SPECIFICINFORMATION FOR
 BUCK DETAIL FASTENING.CLEARLY SPECIFY TAPCON SIZE AND
 SPACING FOR 1X AND 2X BUCKS. INFORMATION FOR DOOR AND
 WINDOW INSTALLATION SHALL BE SHOWED IN THE PRODUCT
 APPROVAL. OMIT THIS INFORMATION TO AVOID CONFUSIONS AND
 CONFLICTS WITH PRODUCT APPROVALS.
  
 F) OUTLOOKER DETAIL:CLARIFY HOW INSTALLING THE
 5/8" CDX PLYWOOD W/(3)8D NAILS @ 6" O.C.?. SEC. 106.1.2
 CITY AMENDMENTS TO FBC 2004.
  
 G) WALL SECTION AT EXISTING WALL: CLARIFY HOW
 INSTALLING 2"X4" P.T. LEDGER W/ (3)16D 12" O.C.?SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 8- ONLY TWO SETS OF EVERYTHING IS REQUIRED. THREE SETS
 ARE NOT REQUIRED.
  
 9- OWES $764.22 FOR UPDATED VALUATION AND RADON FEES AS
 REQUIRED BY SEC. 108.3 CITY AMENDMENTS TO FBC 2004.
  
 10- PROVIDE PRODUCT APPROVALS AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS.PROVIDE THE FLORIDA PRODUCT APPROVAL COVER PAGE
 AND PAGE SHOWING THE CONNECTOR ONLY TO EXPEDITE REVIEW
 PROCESS AND SAVE PAPER.
  
 B) SINGLE HUNG WINDOWS.PROVIDE THE INFORMATION
 THAT WAS SUBMITTED TO OBTAIN THE FLORIDA PRODUCT
 APPROVAL.INFORMATION SUBMITTED IS NOT THE ONE
 SUBMITTED FOR APPROVAL. GO TO FLORIDA PRODUCT APPROVAL
 WEBSITE WWW.FLORIDABUILDING.ORG AND DOWNLOAD
 CORRESPONDING INFORMATION.AND, PROVIDE ONLY THE
 DRAWINGS FOR THE SPECIFIC WINDOW MODEL TO BE USED.
  
 C) EXTERIOR DOOR. PROVIDE FLORIDA PRODUCT APPROVAL
 COVER PAGE WITH 2004 CODE VERSION. ONE SUBMITTED IS FOR
 2001.
  
 D) FLAT ROOF ASSEMBLY:
 * PROVIDE 2004 CODE VERSION. ONE SUBMITTED IS FOR
 2001.
 ** NOA #01-0129.15 EXPIRED ON 05/03/06.
 *** SELECTED ASSEMBLY ON PAGE 22 OF NOA SUBMITTED IS
 FOR INSULATED DECK.ACCORDING TO PLANS THERE IS NOT
 INSULATED ASSEMBLY. REVISE AS REQUIRED.
 **** IF SELECTED ASSEMBLY HAS MORE THAN ONE BASE SHEET
 FASTENING OPTION, THEN MARK SPECIFIC FASTENING OPTION.
 ***** PROVIDE RAS 117 CALCULATIONS FOR NAIL ENHANCING
 AT PERIMETER AND CORNER AREAS AS REQUIRED BY GENERAL
 LIMITATION #7.
  
 11- ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND
 APPROVE IN WRITING (NOT SIGNING AND SEALING)BY THE
 ENGINEER OF RECORD. ENGINEER CAN'T NOT SIGN AND SEAL
 THESE PRODUCT APPROVALS BECAUSE HE DIDN'T DESIGN THEM.
  
 *** ALSO, MAKE SURE NAME OF ENGINEERING APPROVING
 PRODUCT APPROVALS IS PROVIDED ALSO.
  
 12- ENERGY CALCULATIONS:
 A) NEED TO USE REVISED 2006 FORM.
  
 B) CLARIFY WHY CONDITIONED AREA ON ITEM 6 IS
 DIFFERENT THAT CEILING AREA ON ITEM 10.
  
 C) COORDINATE CEILING INSULATION VALUE WITH PLANS.
 INFORMATION SUBMITTED DOESN'T MATCH.
  
 13- SOIL TEST REPORT:
 * LETTERHEAD NEED TO PROVIDE THE ENGINEERING FIRM
 CERTIFICATE OF AUTHORIZATION NUMBER AS REQUIRED BY SEC.
 471 FLORIDA STATUTE AND SEC. 61G15-23.002 OF FLORIDA
 ADMINSITRATIVE CODE.
 ** PROVIDE KEY PLAN SHOWING LOCATION OF BORING TESTS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561) 805-6712