| 2007-06-26 16:04:27 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| | CODE |
| | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC |
| | FLORIDA ADMINISTRATIVE CODE |
| | FSFLORIDA STATUTE |
| | |
| | COMMENTS FROM PREVIOUS LIST: |
| | |
| | 1.)THIS JOB DOES NOT FALL UNDER ANY OF THE EXCEPTIONS |
| | TO ARCHITECTURE, FS481.229.THEREFORE, ALL PLANS |
| | REQUIRED TO SHOW CODE COMPLIANCE ARE REQUIRED TO BE |
| | PREPARED BY A DESIGN PROFESSIONAL. |
| | |
| | 2ND REVIEW; SITE PLAN NOT SEALED. |
| | |
| | 2-3.)ADDRESSED. |
| | |
| | 4.)THE ENGINEERING STATES THAT THIS IS A SINGLE |
| | FAMILY HOME, BUILDING HEIGHT LESS THAN 60', OPEN |
| | STRUCTURE, IMPORTANCE FACTOR OF .77.PLEASE REVISE |
| | THESE NOTES TO BE SPECIFIC TO THIS JOB, WHICH IS A HIGH |
| | RISE. |
| | |
| | 2ND REVIEW - HEIGHT AND IMPORTANCE FACTOR WERE NOT |
| | REVISED AND PRESSURES APPEAR VERY LOW.THIS BUILDING |
| | IS A HIGH RISE, AND AS SUCH THE GUARD SHACK IS SUBJECT |
| | TO THE SAME PRESSURES AS THE BUILDING.NOTE THAT WIND |
| | TUNNEL TEST REPORT MAY BE AVAILABLE. |
| | |
| | 5.)INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6 |
| | (INCLUDE A OR B), BUILDING HEIGHT, SPRINKLER |
| | INFORMATION, OCCUPANCY CLASSIFICATION FBC 3. |
| | |
| | 2ND REVIEW - THIS REFERS TO THE BUILDING.PROVIDE |
| | BUILDING HEIGHT AS PRESSURE INFORMATION IS AFFECTED. |
| | |
| | 6.)SEE FBC603 REGARDING COMBUSTIBLES.SEE ALSO NOTES |
| | 5 AND 6 ON SHEET 3 OF 3, ELITE PANELS, LIMITATIONS & |
| | CONDITIONS OF USE.CODE REQUIREMENTS AND COMPLIANCE |
| | ARE TO BE INCORPORATED INTO THE PLAN. |
| | |
| | 2ND REVIEW - THE RESPONSE STATES "OK".HOW IS THIS |
| | ADDRESSED ON THE PLAN? |
| | |
| | 7.)DOCUMENTS PREPARED BY AN ARCHITECT AND SUBMITTED |
| | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED |
| | ORIGINALS (SITE PLAN). |
| | |
| | 8.)ADDRESSED. |
| | |
| | 9.)IF THIS IS A FULLY SPRINKLERED BUILDING, FIRE |
| | SPRINKLERS WILL BE REQUIRED IN THIS NEW ROOM.FIRE |
| | SPRINKLER PLANS ARE REQUIRED,FBC*106.3.5.1.1(5), |
| | FS553.79 (2). |
| | |
| | 2ND REVIEW - IF THIS BUILDING WITHIN A FULLY |
| | SPRINKLERED BUILIDING HAS A ROOF, FIRE SPRINKLER PLANS |
| | (WITH THE NEW SPACE SPRINKLERED) REQUIRED. |
| | |
| | 10.)PROVIDE COMPONENT AND CLADDING DESIGN |
| | INFORMATION, FBC1603.1.4. |
| | |
| | 2ND REVIEW - SEE OTHER COMMENTS; APPEARS LOW. |
| | CLARIFY. |
| | |
| | 11.) PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER |
| | OF RECORD, FBC*106.3.3. |
| | |
| | 12.)THE PLAN STATES THAT THE GLASS IS TO BE IMPACT, |
| | BUT NON IMPACT PRODUCT APPROVALS WERE SUBMITTED. PLEASE |
| | ADDRESS.ALSO SEE ATTACHED POLICY, ITEM 13, REGARDING |
| | USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS. |
| | |
| | 2ND REVIEW - STATES THAT NONHABITABLE SPACE DOES NOT |
| | REQUIRED IMPACT PROTECTION.PLEASE REMOVE STATEMENT AS |
| | THIS IS NOT A STANDALONE STRUCTURE UNDER ANY |
| | EXCEPTIONS.IMPACT PROTECTOIN IS REQUIRED. |
| | |
| | 13.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED |
| | FOR THE ELITE PANEL, FAC9B72.THE PAPERWORK SUBMITTED |
| | DOES NOT INCLUDE THE FLORIDA STATE PRODUCT APPROVAL. |
| | |
| | 2ND REVIEW - APPLICATION IS PENDING.PLEASE APPLY FOR |
| | LOCAL PRODUCT APPROVAL; APPLICATION IS ATTACHED. |
| | |
| | 14.)A SIDE HINGE DOOR IS REQUIRED, FBC1001.1, |
| | FBC1008.1.2 UNLESS THE SLIDING DOOR COMPLIES WITH |
| | FBC1008.1.3.3. |
| | |
| | 15.)THIS WORK (DOOR AND WINDOW INSTALLATION) DOES NOT |
| | FALL UNDER THE SCOPE OF WORK OF AN ALUMINUM SPECIALTIES |
| | CONTRACTOR.NOTE THAT THIS IS A U LICENSE AND THE PALM |
| | BEACH COUNTY WEBSITE IS UNAVAILABLE, SO I CANNOT |
| | CONFIRM LICENSING AT THIS TIME. |
| | |
| | 2ND REVIEW - PLEASE COMPLETE ANOTHER PERMIT APPLICATION |
| | AS A PORTION OF THE WORK IS TO BE PERMITTED WITH THE |
| | ALUMINUM SPECIALTIES LICENSE AND A PORTION IS TO BE |
| | PERMITTED WITH THE GLAZING LICENSE.TWO DIFFERENT |
| | PERMIT NUMBERS WILL BE ISSUED. |
| | |
| | 16.)THE SITE PLAN IS TO BE PROVIDED IN A LEGIBLE |
| | FORMAT, TO SCALE, FBC106.SHOW THE PROPOSED |
| | IMPROVEMENT, TO SCALE, ON THE SITE PLAN.EXITING |
| | INFORMATION, FBC10, SHOULD BE CLEAR ON THE SITE PLAN. |
| | |
| | |
| | |