Plan Review Notes
Plan Review Notes For Permit 07050433
Permit Number 07050433
Review Stop P
Sequence Number 1
Notes
Date Text
2007-06-26 09:22:56DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 IF IT IS THE INTENT TO USE IRRIGATION PLAN 4 OF 16 FOR
 REFERENCE TO THE PAVERS ONLY PLEASE CLEARLY INDICATE
 THIS AND CROSS OUT ANY REFERENCE TO THE IRRIGATION. IF
 IT IS THE INTENT TO SUBMIT IRRIGATION PLAN SHEET 4 OF
 16 WITH WHAT APPEARS TO BE A PAVING PERMIT THEN IT MUST
 COMPLY WITH THE FOLLOWING. IF IT IS NOT YOUR INTENT TO
 HAVE THE IRRIGATION PLAN WITH THIS PERMIT APPLICATION
 PLEASE REMOVE IT FOR THE RESUBMITTAL.
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET 1 OF 1 AND 4 OF 16:
 IF THE DESIGN PROFESSIONAL IS A
 LANDSCAPE ARCHITECT REGESTERED UNDER THE
 LAWS OF THIS STATE REGULATING THE
 PRACTICE OF LANDSCAPE ARCHITECTURE AS
 PROVIDED FOR IN CHAPTER 481, FLORIDA
 STATUTES, PART LL, THEN HE OR SHE SHALL
 AFFIX HIS OR HER SEAL, SIGNATURE AND
 DATE TO SAID DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA AS DEFINED IN
 SECTION 481.303(6)(A)(B)(C)(D),FS.
  
 2. SHEET 4 OF 16:
 COMMERCIAL IRRIGATION DRAWINGS SHALL CLEARLY INDICATE
 THE FOLLOWING:
 A} CONTROL PANEL
 B} RAIN SENSOR
 C} TIME CLOCK
 D} WATER SOURCE
 A- IF ITS CITY WATER, PLEASE INDICATE SO ON PLANS
 ALONG WITH THE BACKFLOW PREVENTER LOCATION.
 B- IF ITS A WELL, PLEASE INDICATE SO ON THE PLANS
 ALONG WITH THE PUMP LOCATION.
 C- IF ITS PUMPED FROM A LAKE/CANAL, PLEASE INDICATE
 SO ON THE PLANS ALONG WITH THE PUMP LOCATION.
 E} IF WITHDRAWAL OF WATER IS FROM EITHER CLEAR LAKE OR
 LAKE MANGONIA A REVOCABLE PERMIT IS REQUIRED FROM CITY
 HALL/ PUBLIC UTILITIES/ CUSTOMER SERVICE DEPARTMENT/
 202 2ND STREET, WEST PALM BEACH, 1ST FLOOR.
  
 3. SHEET 4 OF 16:
 A} AUTOMATIC IRRIGATION CONTROLLER: THE CONTROLLER
 SHALL BE CAPABLE OF INCORPORATING A RAIN SHUT OFF
 DEVICE TO OVERRIDE THE IRRIGATION CYCLE WHEN ADEQUATE
 RAINFALL HAS OCCURED, AS REQUIRED BY FLORIDA STATUTES,
 SECTION 373.62.
 B} THE RAIN SWITCH SHALL BE PLACED ON A STATIONARY
 STRUCTURE MINIMUM OF 5-FOOT (1524MM) CLEARANCE FROM
 OTHER OUTDOOR EQUIPMENT, FREE AND CLEAR OF ANY TREE
 CANOPY OR OTHER OVERHEAD OBSTRUCTIONS, AND ABOVE THE
 HEIGHT OF THE SPRINKLER COVERAGE.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721