| Date |
Text |
| 2007-05-04 13:48:17 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY |
| | |
| | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH |
| | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. |
| | |
| | ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING |
| | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY; |
| | MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF |
| | EACH ROOF TYPE |
| | |
| | _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL |
| | REQUIRED IN ADDITION TO THE EVALUATION REPORT |
| | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG.THE FL |
| | PRODUCT APPROVAL PRINTED IS FOR THE LIBERTY SYSTEM. |
| | THERE IS A DIFFERENT FL PRODUCT APPROVAL FOR THE GAF |
| | MODIFIED. |
| | |
| | _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED |
| | ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER |
| | YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE |
| | LIMITATIONS. |
| | |
| | _XX_5.)REGARDING THE ENHANCED FASTENING NAILING |
| | PATTERN,I CANNOT DETERMINE WHETHER OR NOT IT IS |
| | COMPLIANT DUE TO INSUFFICIENT INFORMATION. NOTE WHICH |
| | FASTENING OPTION YOU ARE USING (SEE ITEM 4).STATE HOW |
| | MANY FIELD ROWS ARE TO BE INSTALLED.ALSO PLEASE |
| | PROVIDE CALCULATIONS FOR THE ENHANCED FASTENING PER |
| | RAS117.THIS IS BEING REQUESTED BECAUSE YOU HAVE A |
| | DIFFERENT FASTENING SPACING FOR THE LAP AND FIELD, BUT |
| | RAS117 REQUIRES THAT BOTH LAP AND FIELD FASTENING BE |
| | THE SAME.THE ALTERNATE FASTENING PATTERN MAY BE |
| | ACCEPTABLE IF IT EXCEEDS THE REQUIREMENTS OF RAS117, |
| | BUT I CANNOT DETERMINE COMPLIANCE WITH THE INFORMATION |
| | PROVIDED.IF YOU USE THE SYSTEM WITH THE -45PSF DP, |
| | 6INCH, 3 ROWS TOTAL (2 FIELD ROWS, ONE ROW AT THE LAP) |
| | REQUIRED AT 6" EACH, SO THE ENHANCED FASTENING |
| | SPECIFIED WOULD NOT BE IN ACCORDANCE WITH RAS117. |
| | |