Plan Review Notes For Permit 07050139
Permit Number 07050139
Review Stop B
Sequence Number 1
Notes
Date Text
2007-05-22 18:11:05 
  
 DENIED
  
 1)THE CITY OF WEST PALM BEACH REQUIRES THE
 FLORIDA STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
 YHS-50 IS COVERED BY FLORIDA STATEWIDE APPROVAL FL#
 5845 THE SERIES 35H (MS) IS NOT AND HAS LOCAL PRODUCT
 APPROVAL
  
 2)NO PRODUCT APPROVALS WERE SUBMITTED FOR THE PGT
 SINGLE HUNG WINDOW UNITS.
  
 3)PROVIDE A KEY PLAN THAT SHOWS ALL EXISTING DOORS
 AND WINDOWS AND THEIR SIZES, THE SQUARE FOOTAGE OF THE
 BUILDING AND THE TYPE OF OCCUPANCY. ALSO PROVIDE THE
 CORRECT WIND EXPOSURE FOR BUILDING SITUATED ON THE
 INTERCOASTAL (EXP. C) AND THE DESIGN PRESSURES FOR THE
 OPENINGS FOR ZONE 4 & 5
  
 4)STATE ON DRAWINGS WHETHER THE STEEL REINFORCING
 WILL BE USED IN THE FRAME TO INCREASE THE DESIGN
 PRESSURE REQUIREMENTS. PLEASE BE AWARE THAT THE STATE
 OF FLORIDA REQUIRES THAT THE MIAMI-DADE NOA PRESSURE
 VALUES SHALL BE DIVIDED BY 1.33 TO COMPLY WITH THE 2004
 FBC (SEE PAGE 3 OF THE FLORIDA COVER SHEETS)
  
 5)PROVIDE THE TYPE OF GLAZING IN THE 35H DOOR AS THE
 DESIGN PRESSURES DIFFER WITH THE DIFFERENT TYPES.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716