| Date |
Text |
| 2008-07-01 09:28:18 | PLUMBING PLAN REVIEW: |
| | REVISION DENIED: |
| | |
| | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH |
| | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO |
| | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE |
| | (F.A.C.), AND FLORIDA STATUTES (F.S.). |
| | |
| | 1. SHEET P-1.1 FIRST FLOOR PLAN DOES NOT REFLECT THE |
| | FIRST FLOOR PLAN ON SHEET A-1. PLEASE CORRELATE THE |
| | FOLLOWING ON SHEET P-1.1 WITH SHEET A-1. PER FBC- |
| | PLUMBING SECTIONS 401.1, 601.1 AND 701.1 SCOPE. |
| | |
| | A} THE 15" PREP SINK AND DISHWASHER IS MISSING AS WELL |
| | AS THE SANITARY AND WATER TO THESE FIXTURES. |
| | |
| | B} THE POT FILLER WATER SUPPLY IS MISSING. |
| | |
| | C} THE 24" DISHWASHER BY THE 36" SINK IS BEING |
| | INDICATED ON THE WRONG SIDE OF THE 36" SINK. |
| | |
| | 2. SHEET P-2.1 SANITARY RISER DIAGRAM DOES NOT REFLECT |
| | THE FIRST FLOOR PLAN ON SHEET A-1. PLEASE CORRELATE THE |
| | FOLLOWING ON SHEET P-2.1 WITH SHEET A-1. PER FBC- |
| | PLUMBING SECTIONS 701.1 AND 901.1 SCOPE. |
| | |
| | A} THE SANITARY AND VENT FOR THE 15" PREP SINK IS |
| | MISSING AS WELL AS THE DRAIN FOR THE DISHWASHER. |
| | |
| | B} THE DISHWASHER DRAIN FOR THE 36" SINK IS BEING |
| | INDICATED ON THE WRONG SIDE OF THE SINK. |
| | |
| | 3. SHEET P-2.1 SANITARY RISER DIAGRAM: DELETE THE SH |
| | BY THE WC IN THE SECOND FLOOR BATH #3 (THIS IS |
| | CONFUSING). PER FBC- PLUMBING SECTION 701.1 SCOPE. |
| | |
| | 4. SHEET P-2.1 DOMESTIC WATER RISER DIAGRAM DOES NOT |
| | REFLECT THE FIRST FLOOR PLAN ON SHEET A-1. PLEASE |
| | CORRELATE THE FOLLOWING ON SHEET P-2.1 WITH SHEET A-1. |
| | PER FBC- PLUMBING SECTION 601.1 SCOPE. |
| | |
| | A} THE HOT AND COLD WATER FOR THE 15" PREP SINK AND |
| | DISHWASHER IS MISSING. |
| | |
| | B} THE WATER SUPPLY TO THE POT FILLER IS MISSING. |
| | (CLEARLY INDICATE IF ITS HOT OR COLD WATER AS SOME POT |
| | FILLERS HAVE BEEN KNOWN TO BE HOT WATER) |
| | |
| | 5. SHEET P-2.1 DOMESTIC WATER RISER DIAGRAM: THE |
| | FOLLOWING FIXTURES NEED WATER-HAMMER ARRESTORS DUE TO |
| | HAVING QUICK-CLOSING VALVES. PER FBC-PLUMBING SECTION |
| | 604.9. |
| | |
| | A} THE HOT WATER SUPPLY TO THE DISHWASHER BY THE 36" |
| | SINK. |
| | |
| | B} THE HOT WATER SUPPLY TO THE DISHWASHER BY THE 15" |
| | PREP SINK. |
| | |
| | C} THE HOT AND COLD WATER TO THE WASHING MACHINE. (ADD |
| | NOTE BY WASHING MACHINE: REFERENCE DETAIL SHEET |
| | P-0.1). |
| | |
| | |
| | ********IMPORTANT INFORMATION******** |
| | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE |
| | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW |
| | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | END OF COMMENTS: |
| | |
| | REVIEW BY: MIKE PERSON |
| | PLUMBING PLANS EXAMINER |
| | PHONE= (561) 805-6730 |
| | FAX= (561) 805-6731 |
| | E-MAIL= [email protected] |