Text |
| 2007-05-12 17:12:18 | | | | | | | DENIED | | | | | | 1)DESIGN PRESSURE IN THE 2004 FBC HAVE BEEN UPDATED | | | WITH THE 2006 AMENDMENTS, ANY BUILDING IN A NORMALLY | | | EXPOSURE BCATEGORY THAT HAS OPEN TERRAIN (INCLUDES | | | BODIES OF WATER, GOLF COURSES, ETC) IN ANY QUADRANT FOR | | | A DISTANCE OF 600 FT WILL BE CONSIDERED EXPOSURE C. | | | | | | 2)SHUTTER PERMIT APPLICATIONS REQUIRE A KEY PLAN, | | | SHUTTER SCHEDULE CLEARLY MARKED WITH THE INFORMATION | | | SPECIFIC TO THE SITE (TYPE OF CONSTRUCTION, MOUNTING | | | CONNECTION TYPE, ANCHOR TYPE, ETC.) PLEASE SEE THE | | | ATTACHED UPDATED SCHEDULE AND THE DRAWINGS THAT ARE | | | PART OF THE PRODUCT APPROVALS TO CORRESPOND WITH THE | | | SCHEDULE. ****** PLEASE SEE THAT THE DRAWINGS HAVE MANY | | | ITEMS NOT ON SCHEDULE CIRCLED, INCREASES FOR EXPOSURE C | | | WILL NOT REACH SPANS REQUIRED, CONNECTION TYPES CHOSEN | | | DO NOT MATCH ANCHOR SPACING AND TAPCONS, EDGE DISTANCE | | | CIRCLED DO NOT MATCH SCHEDULE. ******* | | | | | | 3)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|