2007-06-19 18:25:25 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE TOTAL FEES DUE FOR INCREASED VALUE AND RADON ARE $
 64.70.
  
 3)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF
 THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS
 PER 106.1 FBC 2004. THE EXEMPTION FROM LICENSURE UNDER
 481.229 FS DOES NOT EXEMPT THE DESIGNER RESPONSIBLE FOR
 THE DRAWINGS FROM SIGNING AND DATING SAID DRAWINGS.
  
 4)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 5)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 6)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 7)PROVIDE SCHEDULE FOR PRE CAST LINTEL THAT WILL BE
 USED AND OPENING SIZES TO COMPLY WITH 2104.1.5 FBC
  
 8)PROVIDE STAIR CONSTRUCTION REQUIREMENTS, RISE, RUN
 TOTAL HEIGHT, ETC. PER 106.3.5 FBC
  
 9)PROVIDE ALL DOOR AND WINDOW DESIGN PRESSURES
  
 10)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES
 OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND
 THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORGPLEASE NOTE THAT PRODUCT
 APPROVALS MUST BE UP TO DATE
  
 11)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 12)PROVIDE PRODUCT APPROVALS FOR THE DOUBLE DOORS
 (FRENCH?) , METAL ENTRY DOOR,MODIFIED ROOFING
 MATERIAL (BE SURE TO PICK THE CORRECT SYSTEM FROM THE
 NOA AND CALCULATE THE ENHANCED FASTENING THAT WILL BE
 REQUIRED FOR THE EDGE AND CORNER ZONES) AND ROOFING
 TILES
  
 13) CLARIFY WHAT WILL BE USED FOR ROOF TILE THE
 DRAWINGS SPECIFY CERAMIC TILES AND THE PRODUCT APPROVAL
 SUBMITTED IS FOR METAL DECRA TILES
  
 14)THE GARAGE DOOR PRODUCT APPROVAL DOES NOT MEET THE
 DESIGN PRESSURE THAT IS REQUIRED
  
 THE FOLLOWING INFORMATION IS REQUIRED FOR
 CLARIFICATION:
  
 15)THE 2ND FLOOR PLAN SHOWS 4" SLAB AND THE WALL
 SECTIONS ON AS-4 AND AS-5 SHOW 6"
  
 16)BREEZEWAYHEIGHT ON A/3 NORTH ELEVATION SHOWN AS
 20'-8"
  
 17)BREEZEWAY TRUSS PLAN ON AS-7 SHOW CONNECTOR AS
 MTSM 16 THIS IS A TRUSS TO MASONRY CONNECTOR, WHILE
 TRUSSES ARE CONNECTED TO WOOD BEAM
  
 18)THE ELEVATION SHOWN ON ON A/3 OF 10'-4" PLEASE
 VERIFY IF THIS IS THE TOP OF BEAM/ CONCRETE FLOOR. NOTE
 THAT WALL SECTIONS AS-4 AND AS-5 SHOW 10'-0"
  
 19)PROVIDE THE INSULATION VALUE, METAL STUD SIZE AND
 THE ATTACHMENT METHOD OF THE STUDS FOR THE DRYWALL
 CEILING LOAD.
  
 20)PROVIDE A SECTION TROUGH THE CEILING/ ROOF IN THE
 OPPOSITE DIRECTION TO BETTER SEE THE APPLICATION OF THE
 DIFFERENT LAYERS. IT IS VERY CONFUSING ON WALL SECTION
 PAGE AS-5 WITH ARROWS POINTING TO THE SAME MATERIAL AS
 INSULATION, 2X4 SLEEPER AND LIGHTWEIGHT CONCRETE
  
 21)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  