| Date |
Text |
| 2007-06-12 17:54:04 | |
| | |
| | DENIED |
| | |
| | 1)BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SETS OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561) 233-5025 FOR MOREINFORMATION. |
| | |
| | 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| | SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| | ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| | ADDED TO THE PERMIT APPLICATION FEES |
| | |
| | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC*. FEES ARE DUE FOR THE STATE RADON AND |
| | THE INCREASED PERMIT VALUE IN THE AMOUNT OF $ 241.32 |
| | THIS MUST BE PAID BEFORE FURTHER PLAN REVIEW IS MADE. |
| | |
| | 4)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| | 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| | SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| | |
| | |
| | 5)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT |
| | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR |
| | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND |
| | APPROVED BY THE DESIGNER OF RECORD. PLEASE SEE THAT |
| | FOUNDATION PLAN HAS AN OUT TO OUT MEASUREMENT OF 17'-2" |
| | AND THE TRUSS ENGINEERING STATES 18'-2"ALSO PER |
| | 106.1.3 FBC* THE BUILDING OFFICIAL MAY ESTABLISH |
| | THROUGH DEPARTMENTAL POLICY, STANDARDS FOR PLANS AND |
| | SPECIFICATIONS "NO WHITE OUT, PENCIL OR INK" |
| | |
| | 6)AN ENGINEER PRACTICING THROUGH A DULYAUTHORIZED |
| | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND |
| | LICENSE #, AS WELL AS THE NAME, ADDRESS AND CERTIFICATE |
| | OF AUTHORIZATION #ON EACH SHEET PER |
| | 61G15-23.002 (2) FAC |
| | |
| | 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| | STATE PRODUCT APPROVAL COVER |
| | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| | SUBMITTED APPLICATIONS WILL BE DENIED |
| | |
| | 8)PLEASE CORRECT THE DISCREPANCY BETWEEN THE |
| | FOUNDATION PLAN OVERALL MEASUREMENT OF 52'-0" AND THE |
| | FLOOR PLAN OF 51'-11" |
| | |
| | 9)TRUSS LAYOUT ON T/1 HAS NOTES FOR MARK "C" THAT |
| | CALL FOR META12 STRAPS BUT THE UPLIFT TABLE HAS TYPE D |
| | WHICH IS A HETA20. THE META12 DOES NOT MEET THE UPLIFT |
| | VALUE FROM THE TABLE. PLEASE CLARIFY |
| | |
| | 10)THE FOLLOWING CORRECTIONS ARE REQUIRED FOR THE |
| | PRODUCT APPROVALS: |
| | A)PRODUCT APPROVALS ARE REQUIRED FOR CASTCRETE |
| | LINTELS OR THE FLORIDA STATEWIDE APPROVAL NUMBER ADDED |
| | TO THE LINTEL SCHEDULE |
| | B)PRODUCT APPROVALS ARE REQUIRED FOR SIMPSON/USP |
| | CONNECTOR OR THE STATEWIDE APPROVAL NUMBERS MAY BE |
| | ADDED TO THE CONNECTOR SCHEDULE |
| | C)PROVIDE THE TYPE OF ASSEMBLY FROM THE GAF RUBEROID |
| | PRODUCT APPROVAL THAT WILL BE USED ON THE ROOF. PLEASE |
| | NOTE THAT IN 140 MPH EXP B THE ZONE 3 AREA OF THE ROOF |
| | HAS A PSF VALUE OF -89.0, MOST ASSEMBLIES MAX OUT AT |
| | -75 PSF WITH A LIMITATION #7 (SEE PAGE32) THAT REQUIRES |
| | CALCULATIONS TO ENHANCE THE FASTENERS TO MEET THE ZONE |
| | 3 REQUIREMENTS. HAVE DESIGNER OF RECORD PROVIDE THESE |
| | CALC'S. |
| | D)POMA STORM PANEL NOA HAS EXPIRED, NEW NOA NUMBER IS |
| | NOW POSTED ON MIAMI-DADE SITE BUT NOT UNDER POMA |
| | |
| | 11)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| | FBC. BE SURE THAT THEY ARE SIGNED AND |
| | DATED BY PREPARER AND OWNER/AGENT PRIOR |
| | TO SUBMITTAL. MAKE CORRECTIONS FOR FLAT ROOF TYPE |
| | |
| | 12)A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |