Plan Review Notes
Plan Review Notes For Permit 07040703
Permit Number 07040703
Review Stop M
Sequence Number 1
Notes
Date Text
2007-04-25 10:56:38*** DENIED ***
 1) MECHANICAL PLANS PAGE M1.1 SHOW NO SUPPLY OR RETURN
 AIR GRILLS FOR GUEST BEDROOM #106, PLEASE CORRECT.
  
 2) PLEASE SHOW CLOTHES DRYER VENT ON MECHANICAL PLANS,
 SEE 2004 FBC/M 504.
  
 3) PLEASE SHOW ON PLANS DOOR D15 TO EXISTING MECHANICAL
 ROOM AT MASTER HALL IS A NONCOMBUSTIBLE DOOR, SEE 2004
 FBC.M 602.2.1.
  
 4) MECHANICAL PLANS PAGE M1.1 SHOWS IN LIVING ROOM #102
 AND SITTING #114, "1 INCH R.A. SLOT CONTINUOUS, SEE
 ARCH. DWG.". COULD NOT FIND ANY ARCHITECTURAL DRAWING
 FOR THIS, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.