| 2007-04-25 06:26:26 | BUILDING PLAN REVIEW |
| | PERMIT: 07040689 |
| | ADD: 2235 OKEECHOBEE BLVD |
| | CONT: BENCHMARK III CORP |
| | TEL: (561)744-8686 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | REVIEW 1ST |
| | ACTION: DENIED |
| | |
| | 1)THE DRAWINGS SHALL SHOW COMPLIANCE WITH SECTIONS |
| | 11-4.22.2 DOORS.(1)ALL DOORS TO ACCESSIBLE TOILET |
| | ROOMS SHALL COMPLY WITH SECTION 11-4.13 . DOORS SHALL |
| | NOT SWING INTO THE CLEAR FLOOR SPACE REQUIRED FOR ANY |
| | FIXTURE. SEE SECTIONS 11-422.3 -11-4.22.7. |
| | |
| | 2)11-4.26.1ALL HANDRAILS, GRAB BARS, AND TUB AND |
| | SHOWER SEATS REQUIRED TO BE ACCESSIBLE BY SECTION |
| | 11-4.1 , 11-4.8 , 11-4.9 , 11-4.16 , 11-4.17 , 11-4.20 |
| | OR 11-4.21 SHALL COMPLY WITH SECTION 11-4.26 . INDICATE |
| | THE TYPE OF BACKING WHICH WILL MEET THE 250LB BENDING |
| | MOMENT REQUIREMENT STATED IN SECTION(11-4.26.3). |
| | |
| | 3) THE CERTIFICATE OF AUTHORIZATION NUMBER OF ARCHITECT |
| | AND ASSOCIATES, P.A.SHALL BE INDICATED IN THE TITLE |
| | BLOCK ON EACH PAGE. |
| | 61G1-16.004 TITLE BLOCK. |
| | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR |
| | INTERIOR DESIGN DRAWINGS AND SPECIFICATION |
| | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A |
| | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: |
| | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. |
| | (2) FIRM LICENSE NUMBER. |
| | (3) NAME OR IDENTIFICATION OF PROJECT. |
| | (4) DATE PREPARED. |
| | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. |
| | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING |
| | THE DOCUMENT. |
| | |
| | 4 ) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| | THE COURT. |
| | NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| | |
| | 5)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| | PER 108.3 FBC* |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | 805-6726 |
| | |
| | |