Plan Review Notes
Plan Review Notes For Permit 07040578
Permit Number 07040578
Review Stop B
Sequence Number 4
Notes
Date Text
2007-09-05 15:37:43TRUSS DRAWING SUBMITTAL
  
 DENIED BY BUILDING
  
 1) THE TRUSS DRAWING COVERSHEET REFERENCES THE 2001 FBC
 AND THE CORRECT CODE IS THE 2004 FBC.
  
 2) THE DESIGNER (ARCHITECT) OF RECORD FOR THE STRUCTURE
 CAN NOT SIGN AND SEAL THE TRUSS LAYOUT OR TRUSS
 DRAWINGS AS THE DESIGN OF THESE ARE THE RESPONSIBLITY
 OF THE TRUSS ENGINEER.THE DESIGNER OF RECORD IS ONLY
 REQUIRED TO REVIEW THE LAYOUT AND DRAWINGS FOR
 CONFORMANCE TO HIS DESIGN FOR THE STRUCTURAL LOADS. HE
 IS REQUIRED TO APPROVE IT OR SPECIFY CHANGES IN
 WRITING.A SHOP DRAWING REVIEW STAMP INITIALED BY THE
 DESIGNER OF RECORD IS ALL THAT IS REQUIRED.
  
 3) THE TRUSS DRAWINGS ARE NOT REQUIRED TO BE SUBMITTED
 FOR REVIEW FOR ONE AND TWO FAMILY STRUCTURES AND CAN BE
 GIVEN TO THE FIELD INSPECTOR AT TIME OF ROOF FRAMING
 INSPECTION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
  