 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MOREINFORMATION.
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES AND $2.82 IS DUE.
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4)PROVIDE SITE PLAN 2 COPIES OF A RECENT SURVEY
 SHOWING THE PROPOSED BUILDING/ADDITION WITH ALL SIDE
 AND REAR SETBACKS
  
 5)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND
 THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 8)SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 9)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 10)THE FOLLOWING ARE REQUIRED ON THE DRAWINGS
 A)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT AND
 ROOF PITCH
 B)PROVIDE MIN ROOF SHEATHING ATTACHMENT
 PER R803.2.3.1 FBC RES.
 C)PROVIDE INFORMATION ON EXISTING BUILDING, SURVEY
 SHOWS EXISTING TO BE CBS DRAWINGS SHOW NEW AS WOOD
 FRAME. WHAT ATTACHMENT METHODWILL BE USED FOR WALLS
 AND IS THE EXISTING FLOOR WOOD ON STRIP FOOTING OR SLAB
 ON GRADE
 D)PROVIDE DETAIL ON LVL BEAM ELEVATION AND ATTACHMENT
 AT EXTERIOR WALL. IS BEAM FLUSH TO CEILING WITH HANGERS
 FOR EXISTING ROOF MEMBERS OR DROPPED WITH EXISTING ROOF
 ON TOP
 E)PROVIDE FLORIDA STATE APPROVAL #'S FOR ANCHORS AND
 TIES IN THE TRUSS ANCHOR SCHEDULE OR PROVIDE PRODUCT
 APPROVALS
 F)PROVIDE A COMPLETE WALL SECTION FOOTING THROUGH
 ROOF, TO INCLUDE INSULATION VALUES THAT MATCH ENERGY
 CALC'S, ROOF SHEATHING ATTACHMENT IF NOT ANYWHERE
 ELSE,ETC.
  
 11)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  