| Plan Review Notes For Permit 07040420 |
| Permit Number |
07040420 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2007-06-19 09:02:25 | DENIED; | | | 1. BREAK SINK KNEE CLEARANCE NOT ADDRESSED. (SECOND | | | REQUEST) PAGE 3.1 DETAIL A-7 (BREAK SINK) CABINET DOORS | | | NOT PERMITED ON CABINET UNDER SINK. NO DOOR PERMITED TO | | | SWING INTO THE CLEAR FLOOR SPACE. THE LOCATION OF THE | | | SUMP PUMP MUST NOT LOCATED IN THE CLEAR FLOOR SPACE | | | UNDER THE BREAK SINK. SHOW LOCATION OF PUMP ON PLANS | | | WITH NOTE. | | | 2. PAGE D-1 NOTE 3, EXISTING CABINTRY, SINK AND PIPES | | | TO BE REMOVED. NO DEAD ENDS MORE THAN 2' PERMITED IN | | | THE SANITARY PLUMBING SYSTEM. | | | 3. COMMENTS BY ELECTRICAL AND MECHANICAL PLAN REVIEWS ( | | | ADMINISTRATION CODE PROBLEMS)MUST ALSO BE ADDRESSED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|