Plan Review Notes
Plan Review Notes For Permit 07040043
Permit Number 07040043
Review Stop B
Sequence Number 1
Notes
Date Text
2007-04-28 10:46:18 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC* VALUE HAS BEEN INCREASED AND FEES ARE
 DUE THESE MUST BE PAID PRIOR TO FURTHER REVIEW
  
 2)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MOREINFORMATION.
  
 3)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF
 THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS
 PER 106.1 FBC 2004. THE EXEMPTION FROM LICENSURE UNDER
 481.229 FS DOES NOT EXEMPT THE DESIGNER RESPONSIBLE FOR
 THE DRAWINGS FROM SIGNING AND DATING SAID DRAWINGS.
  
 4)WORK ON EXISTING BUILDINGS IS COVERED UNDER THE FBC
 (EXISTING) AS SUCH A DESIGN PROFESSIONAL OR OWNERMUST
 ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION PER
 301.5 FBC (EXISTING)
  
 5)PROVIDE 2 COPIES OF SURVEY THAT SHOW THE PROPOSED
 ADDITION WITH SETBACK FROM PROPERTY LINES INDICATED
  
 6)PROVIDE A SITE PLAN THAT SHOWS CORRECT MEASUREMENTS
 THAT MATCH SURVEY.
  
 7)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
 SHOWDRAINAGE FROM BUILDINGAND AWAY FROM ADJOINING
 PROPERTIES
  
 8)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE
 OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2
 COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER
 R401.4 FBC RES.
  
 9)PROVIDE BEAM/LINTEL DETAIL. TOB = 8'-0" DOOR IS
 6'-8" IN ORDER TO FIT 8" BOND BEAM AND 8" LINTEL DOOR
 WILL NOT FIT. IF POURED DROP DOWN BEAM IS USED SHOW
 DETAIL. ALSO WILL BE REQUIRED FOR WINDOWS IF SAME
 ELEVATION IS USED.
  
 10)DRAWING DOES NOT SHOWACCESSIBLE BATHROOM THAT
 COMPLIES WITH R322.1.1 FBC RES. W/C DOOR SIZE NOT
 PROVIDED.
  
 11)IDENTIFY SAFETY GLAZING FOR SHOWER DOOR THAT MEETS
 PROVISIONS OF R308.4 FBC RES.
  
 12)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS
 REQUIRED PER R807.1 FBC RES.
  
 13)SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 14)PROVIDE ENGINEERED SUBSTRATE ATTACHMENT FOR WOOD
 BUCKS PER 1714.5.4.1 FBC
  
 15)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND
 THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 16)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 17)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
  
 18)PLEASE PROVIDE (2) COPIES OF THE PRODUCT APPROVALS
 THAT PERTAIN TO BUILDING (NO FIXED WINDOWS ARE SHOWN ON
 THE DRAWINGS)
  
 19)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  