2007-04-16 11:05:57****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)A STRUCTURAL REPAIR DETAIL FOR THE ROOF IS
 REQUIRED PER BUILDING INSPECTOR.
  
 2.)A BUILDING PERMIT WILL BE REQUIRED IN ADDITION TO
 THE ROOF PERMIT.YOU MAY ADD THIS TO THE SCOPE OF WORK
 AND SIGN ON THE APPROPRIATE LINE ON THE PERMIT
 APPLICATION.A NEW PERMIT NUMBER WILL BE GENERATED.
 PLEASE DO THIS WHEN RESUBMITTING THROUGH THE FRONT
 COUNTER.
  
 3.)THE ASSEMBLIES YOU HAVE SELECTED REFER TO GENERAL
 LIMITATION #9.ENHANCED FASTENING CANNOT BE USED, AND
 THE SYSTEM IS LIMITED TO -45PSF.A DESIGN PRESSURE OF
 -89 IS REQUIRED.A SYSTEM WITH GENERAL LIMITATION #7
 MUST BE SELECTED.
  
 4.)SELECT ONLY ONE ASSEMBLY.IF YOU CHANGE THE
 ASSEMBLY, YOU CAN APPLY FOR A REVISION.
  
 5.)SPECIFY ENHANCED FASTENING FOR ZONES 2 AND 3.
  