Notes
Date Text
2007-04-27 11:10:51BUILDING REVIEW CHECKLIST:
  
 1- ARCHITECT TO PROVIDE FIRM'S NUMBER IN THE TITLE
 BLOCK ASREQUIRED BY SEC. 61G1-16.004 FLORIDA
 ADMINISTRATIVE CODE.
  
 2- ROOM CALLED STORAGE IS A BEDROOM.BEDROOM WINDOW
 DOESN'T COMPLY WITH SECTION R310 OF 2004 FLORIDA
 RESIDENTIAL CODE. REVISE AS REQUIRED.
  
 3- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD (561)233-5115)TO VERIFY IF
 IMPACT FEES ARE DUE.BRING BACK STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE.
  
 4- SEE PRODUCT APPROVAL FOR DOOR AND WINDOWS TO VERIFY
 SIZE OF STRUCTURAL BUCK REQUIRED AND PROVIDE STRUCTURAL
 BUCK DETAILS FOR EXTERIOR DOOR AND WINDOWS. SEE SEC.
 R613.6.2 OF 2004 FLORIDA RESIDENTIAL CODE FOR PROPER
 WAY OF INSTALLING THE BUCKS.
  
 5- SPECIFY WINDOW AND DOOR LINTELS. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) PRECAST LINTELS (IF SPECIFIED ON PLANS).
  
 7-ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 8- ENERGY CALCULATIONS:
 A) PROVIDE CURRENT AND REVISED FORM 600C-04 R.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM TOO.
  
 9- WALL SECTION:
 A) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R602.1.2
 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 B) HOW IS THE DRYWALL AND INSULATION INSTALLED.
 DETAIL SHOWN IS INCOMPLETE. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 10- STORM SHUTTERS:
 A) DRAWINGS SUBMITTED DON'T CORRESPOND TO NOA
 #02-0826.07 AND ARE INCOMPLETE. PROVIDE CORRECT AND
 COMPLETE DRAWINGS.
  
 B) PROVIDE COMPLETE INSTALLATIONSCHEDULE AND MARK
 ON DRAWINGS SPECIFIC ANCHOR TYPE AND SPACING TO BE
 USED.SEE ATTACHED SAMPLE OF INSTALLATION SCHEDULE.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 11- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712