| Date |
Text |
| 2007-08-15 11:45:40 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: |
| | |
| | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). |
| | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR |
| | NOI. |
| | YOU CAN GET NOI INFO FROM |
| | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ |
| | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), |
| | EFFECTIVE MAY 1, 2003 |
| | 2. PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & |
| | ITS ENCLOSURE PER CITY OF WPB, LOCATION MUST BE |
| | ACCESSIBLE FOR PICKUP TRUCK. |
| | 3.PLEASE PROVIDECENTER LINE OF ROAD , SIDEWALK |
| | ELEVATION & GRADE ELEVATION TO MEET FLOOD ZONE AREA, & |
| | 5,10, 25, 100 YEAR FLOOD CRITERIA. PLEASE SHOW IN YOUR |
| | STORM WATER QUALITY CALS. |
| | 4. PLEASE PROVIDE TOTAL SITE AREA, PERVIOUS, IMPERVIOUS |
| | AREA, PRE & POST.MAKE SURE THESE SITE AREAS SHOWN ON |
| | DRAWINGS MUST MATCH WITH AREAS USED IN STORM WATER |
| | QUALITY CALCULATIONS. |
| | 5. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES |
| | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM |
| | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL |
| | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, ETC ON DRAWINGS, DO YOU HAVE EXFILTRATION |
| | TRENCHES. PLEASE SHOW DRY DETENTION/WET DETENTION |
| | AREAS. |
| | 6. PLEASE PROVIDE A COPY OF GEO-TECH REPORT AND A |
| | LATESTEST COPY OF STORM STORM WATER QUALITY |
| | CALCULATIONS, PLEASE RESUBMIT NPBCID COPY & SFWMD COPY |
| | THAT YOU PROVIDED. |
| | 7. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | DETAILS,CLOTHES USED FOR SILT ETC., PLANS MUST SHOW |
| | SILT FENCE AROUND THE WHOLE SITE ALONG THE GOLF COURSE |
| | RESIDENTS LIVE& NOT ONLY ON CATCH BASINS & UPSTREAM |
| | OF CULVERT .HEIGHT OF FENCE SHOULD BE HIGH ENOUGH PER |
| | FDEP TO STOP DUST & PARTICLES. |
| | 8. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |