Plan Review Notes
Plan Review Notes For Permit 07030932
Permit Number 07030932
Review Stop B
Sequence Number 3
Notes
Date Text
2007-12-12 10:44:32525 OKEECHOBEE BLVD
 INTECH
 DEC.11, 2007
  
  
  
 BUILDING PLAN REVIEW
 PERMIT: 07030932
 ADD: 525 OKEECHOBEE BLVD PENTHOUSE A & B
 CONT: CENTEX/ BALFOUR BEATTY
 TEL: (954)214-9415
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 3RDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE
 WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT
 ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) SECOND REQUEST, YC J DESIGN WILL REQUIRE A
 CERTIFICATE OF AUTHORIZATION,481.219 F.S.
 CERTIFICATE OF AUTHORIZATION,THE TITLE BLOCK FOR ANY
 SHEET BEARING THE NAME OF AN ARCHITECT PRACTICING UNDER
 A FICTITIOUS NAME, A CORPORATION, OR A PARTNERSHIP,
 OFFERING ARCHITECTURAL SERVICES, SHALL INCLUDE THE
 CERTIFICATE OF AUTHORIZATION NUMBER.
 481.219CERTIFICATION OF PARTNERSHIPS, LIMITED
 LIABILITY COMPANIES, AND CORPORATIONS.--
 (1)THE PRACTICE OF OR THE OFFER TO PRACTICE
 ARCHITECTURE OR INTERIOR DESIGN BY LICENSEES THROUGH A
 CORPORATION, LIMITED LIABILITY COMPANY, OR PARTNERSHIP
 OFFERING ARCHITECTURAL OR INTERIOR DESIGN SERVICES TO
 THE PUBLIC, OR BY A CORPORATION, LIMITED LIABILITY
 COMPANY, OR PARTNERSHIP OFFERING ARCHITECTURAL OR
 INTERIOR DESIGN SERVICES TO THE PUBLIC THROUGH
 LICENSEES UNDER THIS PART AS AGENTS, EMPLOYEES,
 OFFICERS, OR PARTNERS, IS PERMITTED, SUBJECT TO THE
 PROVISIONS OF THIS SECTION.
 3A-C) COMPLIED
  
 3D) THE STRUCTURAL ENGINEER NAIM & ASSOCIATES STILL
 INDICATES THEY ARE THE DESIGNERS FOR THE STAIRS. THEIR
 NAME DOES NOT APPEAR ON THE STRUCTURAL SHEETS BUT DOES
 APPEAR ON THE STAIR 1 & STAIR 2 STRUCTURAL CALCULATIONS
 AS WELL AS THE HANDRAIL CALCULATION. FLORIDA
 ADMINISTRATIVE CODE
 61G15-23.002(2)
 . ENGINEERING REPORTS MUST BE SIGNED, SEALED AND DATED
 ON A SIGNATURE PAGE OR COVER LETTER BY EACH
 PROFESSIONAL ENGINEER WHO IS IN RESPONSIBLE CHARGE OF
 ANY PORTION OF THE REPORT. A PROFESSIONAL ENGINEER MAY
 ONLY SEAL AN ENGINEERING REPORT, PLAN, PRINT OR
 SPECIFICATION IF THAT PROFESSIONAL ENGINEER WAS IN
 RESPONSIBLE CHARGE OF THE PREPARATION AND PRODUCTION OF
 THE ENGINEERING DOCUMENT AND THE PROFESSIONAL ENGINEER
 HAS THE EXPERTISE IN THE ENGINEERING DISCIPLINE USED IN
 PRODUCING THE ENGINEERING DOCUMENT IN QUESTION.
  
  
 4) COMPLIED.
  
 5) THE SAME HOLDS TRUE FOR THECALCULATIONS SUBMITTED
 FOR THE STAIRS BETWEEN THE 15TH & 16TH FLOOR. MUST BE A
 LICENSED ENGINEER FOR THE STATE OF FLORIDA AND IF THE
 ENGINEER OF RECORD DOES NOT SEAL EACH SHEET THEN A
 SEALED COVER SHEET LISTING HOW MANY PAGES ARE COVERED
 UNDER THIS SEAL. 61G15-23.002.THE ENGINEER SIE H WONG
 WILL ASSUME THE WORK AS HIS OWN WITH THE
 CALCULATIONS COMPLETED AND UNDER THAT PERSONS SEAL.
 NOTE ALSO THE REQUIREMENTS FOR COVER SHEET AND OR INDEX
 PAGES OTHERWISE EACH SHEET WILL NEED TO BE SEALED.
 61G15-23.002
 A COVER OR INDEX SHEET FOR ENGINEERING SPECIFICATIONS
 MAY BE USED AND THAT SHEET MUST BE SIGNED, SEALED AND
 DATED BY THOSE PROFESSIONAL ENGINEERS IN RESPONSIBLE
 CHARGE OF THE PRODUCTION AND PREPARATION OF EACH
 SECTION OF THE ENGINEERING SPECIFICATION WITH
 SUFFICIENT INFORMATION ON THE COVER SHEET OR INDEX SO
 THAT THE USER WILL BE AWARE OF EACH PORTION OF THE
 SPECIFICATIONS FOR WHICH EACH PROFESSIONAL ENGINEER IS
 RESPONSIBLE. ENGINEERING REPORTS MUST BE SIGNED, SEALED
 AND DATED ON A SIGNATURE PAGE OR COVER LETTER BY EACH
 PROFESSIONAL ENGINEER WHO IS IN RESPONSIBLE CHARGE OF
 ANY PORTION OF THE REPORT. A PROFESSIONAL ENGINEER MAY
 ONLY SEAL AN ENGINEERING REPORT, PLAN, PRINT OR
 SPECIFICATION IF THAT PROFESSIONAL ENGINEER WAS IN
 RESPONSIBLE CHARGE OF THE PREPARATION AND PRODUCTION OF
 THE ENGINEERING DOCUMENT AND THE PROFESSIONAL ENGINEER
 HAS THE EXPERTISE IN THE ENGINEERING DISCIPLINE USED IN
 PRODUCING THE ENGINEERING DOCUMENT IN QUESTION.
  
 6) COMPLIED.
  
 7A) COMPLIED.
  
 7B) 2ND REQUEST THE LIFE SAFETY PLAN HAVE THE WRONG
 WINDCRITERIA, PLEASE CORRECT TO
 ASCE 7-02.
  
 8-9) COMPLIED
  
 10) SHEET 1-16C INDICATES DOOR TYPED-3(3) LOCATIONS
 WHERE THE DOOR IS CREATING THE OPENING PROTECTIVE 45MIN
 DOOR FOR THE ATRIUM, SHEET I-DR-1 DOES NOT INDICATE
 THIS AS A RATED DOOR, THE PLAN DOES INDICATE D3L AS A
 45MINUTE RATED DOOR. TABLE 715.3.
  
 11-15) COMPLIED
  
 16)PLEASE PROVIDE ADDITIONAL INFORMATION ON THE GLASS
 HANDRAILS AND GUARDS SEE 2407.
 2407.1.1 LOADS. THE PANELS AND THEIR SUPPORT SYSTEM
 SHALL BE DESIGNED TO WITHSTAND THE LOADS SPECIFIED IN
 SECTION 1607.7 . A SAFETY FACTOR OF FOUR SHALL BE
 USED.
  
 2407.1.2 SUPPORT.
 EACH HANDRAIL OR GUARD SECTION SHALL BE SUPPORTED BY A
 MINIMUM OF THREE GLASS BALUSTERS OR SHALL BE OTHERWISE
 SUPPORTED TO REMAIN IN PLACE SHOULD ONE BALUSTER PANEL
 FAIL. GLASS BALUSTERS SHALL NOT BE INSTALLED WITHOUT AN
 ATTACHED HANDRAIL OR GUARD.
  
 THIS WORK MUST BE COMPLETED BY A FLORIDA REGISTER
 PRACTICING ENGINEER.
 FL ADMINISTRATIVE CODE 61G15-23.002(2)
 . ENGINEERING REPORTS MUST BE SIGNED, SEALED AND DATED
 ON A SIGNATURE PAGE OR COVER LETTER BY EACH
 PROFESSIONAL ENGINEER WHO IS IN RESPONSIBLE CHARGE OF
 ANY PORTION OF THE REPORT. A PROFESSIONAL ENGINEER MAY
 ONLY SEAL AN ENGINEERING REPORT, PLAN, PRINT OR
 SPECIFICATION IF THAT PROFESSIONAL ENGINEER WAS IN
 RESPONSIBLE CHARGE OF THE PREPARATION AND PRODUCTION OF
 THE ENGINEERING DOCUMENT AND THE PROFESSIONAL ENGINEER
 HAS THE EXPERTISE IN THE ENGINEERING DISCIPLINE USED IN
 PRODUCING THE ENGINEERING DOCUMENT IN QUESTION.
 17-28) COMPLIED.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  