| 2007-09-24 08:18:50 | MC DONALD?S 9835 OKEECHOBEE BLVD |
| | 3RD REVIEW |
| | SEPT 21,2007 |
| | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 07030860 |
| | ADD: 9835 OKEECHOBEE BLVD |
| | CONT: GIL HYATT CONSTRUCTION |
| | TEL: (954)772-2066 |
| | ? |
| | |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 3RDREVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. PLEASE REMOVE |
| | VOID SHEETS FROM PLAN AND LOOSELY LAY THEM ON TOP OF |
| | THE SET OF PLANS MARKED VOID. THANK YOU FOR YOUR |
| | ANTICIPATED COOPERATION. |
| | |
| | 2 ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT. |
| | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF |
| | COMMENCEMENTIS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS |
| | AFTER THE RECORDING THEREOF,SUCH NOTICE IS NULL & |
| | VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE OF |
| | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST |
| | INSPECTION. |
| | |
| | 3) PLEASE PROVIDE (2) REPORTS WITH ORIGINAL SIGNATURES |
| | NOT COPIED SIGNATURES WITH EMBOSSED SEAL. |
| | FBC 1802.2.1 QUESTIONABLE SOILS, WHERE THE |
| | SAFE-SUSTAINING POWER OF THE SOIL |
| | IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO |
| | THAT SPECIFIED IN THIS CODE ISCLAIMED, THE BUILDING |
| | OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION |
| | BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE |
| | PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . |
| | |
| | 4) BUILDING PROVISO:PROVIDE FLOOD ZONE ELEVATION |
| | CERTIFICATE FOR NEW CONSTRUCTION WITH BASE FLOOD |
| | ELEVATION, CITY CODE REQUIRES |
| | AN ADDITIONAL 6". LOCATED IN A A-O) FLOOD ZONE. |
| | |
| | 5) COMPLIED. |
| | |
| | 6)COMPLIED. |
| | |
| | 7)BUILDING PROVISO: BILCO (ROOF HATCHES) IS CURRENTLY |
| | UNDER GOING TESTING WITH MIAMI-DADE AND REPORTS WILL BE |
| | OUT THE SECOND HALF OF 2007. THE CONTRACTOR WILL BE |
| | REQUIRED TO SUBMIT PRODUCT APPROVALS THAT HAVE |
| | ACCEPTANCE TO THIS OFFICE BEFORE A CERTIFICATE OF |
| | OCCUPANCY WILL BE ISSUED. IF AT TIME OF C.O. EITHER AN |
| | APPROVAL FROM A STATE LISTED AGENCY WILL BE REQUIRED OR |
| | THE CONTRACTOR SHALL APPLY FOR A LOCAL PRODUCT APPROVAL |
| | WITH THE CITY OF WEST PALM BEACH WITH THE SAME 10 |
| | CRITERIA AS THE STATE APPROVALS BEFORE A CERTIFICATE OF |
| | OCCUPANCY WILL BE ISSUED. STATE REQUIREMENTS FOR |
| | STRUCTURAL COMPONENTS AS PER RULE |
| | 9B-72.010(28), FLORIDA ADMINISTRATIVE CODE AND IS |
| | SUBJECT TO THE REQUIREMENTS FOR PRODUCT APPROVAL.. |
| | |
| | 8-14) COMPLIED. |
| | |
| | 15A) THE PRODUCT APPROVALS SUBMITTED ARE UNDER THE 2001 |
| | FBC PLEASE PROVIDE THE APPROVALS THAT ARE CURRENTLY |
| | UNDER THE 2004 FBC. FL BLD CODE 1609.1.4: COMPONENTS |
| | & CLADDING, PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT |
| | INSPECTOR) OF PRODUCT TESTING REPORTS, MISSING REPORTS |
| | ARE AS FOLLOWS: |
| | A) FIXED WINDOWS MISSING THE FL COVER SHEET NOA |
| | 05-0906.05 |
| | B) DRIVE THROUGH WINDOW- MISSING THE FL COVER SHEET NOA |
| | 07-0503.09 |
| | C) GLAZED DOORS- MISSING FL COVER SHEET NOA 05-0829.08 |
| | D) EXTERIOR HOLLOW METAL DOORS- NO FL COVER SHEET NOR |
| | REPORT SUBMITTED |
| | E) ROOF HATCH WILL BE A BUILDING PROVISO |
| | F) TRUSS ANCHORS ? OK FL COVERSHEET AND REPORTS |
| | G) ROOF ASSEMBLIES: |
| | FLAT ROOF ? NO FL COVER |
| | SHEET NOR REPORT SUBMITTED, HIGHLIGHT |
| | |
| | SUBSYSTEM TO BE USED ON PROJECT. |
| | ROOF TILE-POLYGLASS |
| | NOA 06-0505.01 REQUIRES FL COVERSHEET |
| | |
| | 16)PRODUCT APPROVALS SUBMITTED WITH PERMIT |
| | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO |
| | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR |
| | INFORMATION PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE |
| | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER |
| | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, |
| | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR |
| | SITE SPECIFIC FORM PER RULE 9B-72. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 17) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE |
| | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF |
| | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. |
| | |
| | 18-22) COMPLIED. |
| | |
| | 23)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, |
| | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE |
| | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE |
| | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 24 ) BUILDING PROVISO: 109.3.10* IMPACT OF |
| | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY |
| | THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO |
| | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, |
| | UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID |
| | PROPERTY PURSUANT TO A CONSENT BY |
| | THE APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS |
| | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS |
| | INCLUDESBUT IS NOT LIMITED TO THE CONTROL OF DUST, |
| | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE |
| | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION |
| | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE |
| | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY |
| | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH |
| | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS |
| | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, |
| | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL |
| | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, |
| | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ |
| | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A |
| | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED |
| | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS |
| | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A |
| | CERTIFICATE FROM A LICENSED ENGINEER SHALL BE SUBMITTED |
| | TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE |
| | FINAL INSPECTION. |
| | |
| | 25) BUILDING PROVISO:109.3.10.1 HURRICANE PROTECTION. |
| | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW |
| | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO |
| | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION |
| | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN |
| | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN |
| | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, |
| | EQUIPMENT AND DEBRIS SHALL BE EITHER REMOVED FROM THE |
| | CONSTRUCTION SITE OR SECURED IN SUCH A MANNER AS TO |
| | MINIMIZE THE DANGER OF SUCH CONSTRUCTION MATERIALS, |
| | EQUIPMENT AND DEBRIS CAUSING DAMAGE TO PERSONS OR |
| | PROPERTY FROM HIGH WINDS. ANY PERSONS WHO FAILS TO |
| | COMPLY TO REMOVE OR SECURE THE CONSTRUCTION MATERIALS |
| | EQUIPMENT AND DEBRIS WITHIN |
| | 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE |
| | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION |
| | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS |
| | SECTION |
| | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 |
| | OF THIS CHAPTER. |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |
| | |
| | |