| Plan Review Notes For Permit 07030796 |
| Permit Number |
07030796 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2007-04-21 14:11:03 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.)YOU HAVE USED EXPOSURE B PRESSURES, THIS IS | | | EXPOSURE C.REVISE PRESSURES AND REVISE ANCHOR | | | SCHEDULE AS NECESSARY.FOR INSTANCE, OPENING 5, END | | | ZONE, HAS A MINIMUM DESIGN PRESSURE OF -48.16 FOR 50SF, | | | END ZONE, EXPOSURE C.SEE HIGHLIGHTED PRODUCT | | | APPROVAL, 11INCH SPACING REQUIRED.CHECK ALL | | | OPENINGS. |
|