Plan Review Notes
Plan Review Notes For Permit 07030745
Permit Number 07030745
Review Stop B
Sequence Number 1
Notes
Date Text
2007-03-28 08:13:14****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)FAC9B72, THE APPLICATION IS INCOMPLETE.A LETTER
 STATING THAT IN THE ENGINEER'S OPINION THE DOOR MEETS
 WIND LOADS IS NOT A METHOD OF COMPLIANCE.SEE ITEMS 7,
 8 ARE INCOMPLETE.
  
 2.)SEVERAL SHEETS HAVE THE ENGINEER'S SIGNATURE
 WITHOUT ALL INFORMATION REQUIRED BY FAC61G15-23.002 AND
 ARE NOT SEALED AND DATED.
  
 3.)PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS,
 SIZE, TYPE, AND ROOM DESIGNATION FOR BEDROOMS FBC
 1025.1, FBC EB 505.1.
  
 4.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED
 FOR ALL PRODUCTS, FAC9B72.THIS IS REQUIRED IN
 ADDITION TO THE NOAS SUBMITTED.
 WWW.FLORIDABUILDING.ORG
  
 5.)THE PROPOSED DOORS ARE FIRE RATED DOORS.ARE
 THERE FIRE RATING REQUIREMENTS?SHOW ON THE PLAN.
  
  