| Notes |
| Date |
Text |
| 2007-10-30 13:36:15 | ****************PROVISO**************** | | | (A) 802.2 DOMESTIC DISHWASHING MACHINES SHALL | | | DISCHARGE INTO A WYE-BRANCH FITTING ON THE TAILPIECE OF | | | THE KITCHEN SINK OR THE DISHWASHER CONNECTION OF A FOOD | | | WASTE GRINDER. | | | | | | ****************PROVISO**************** | | | PER FBC-2004 PLUMBING, SECTION 704.5 | | | DEAD ENDS: IN THE INSTALLATION OR | | | REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. | | | A DEMO PLUMBING PERMIT REQUIRED AND | | | INSPECTION REQUIRED OF DEMO WORK PRIOR | | | TO COVERING DEMO WORK WITH FINNISH | | | WALLS, CIELINGS, OR POURED CONCRETE | | | SLABS. | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|