| Plan Review Notes For Permit 07030651 |
| Permit Number |
07030651 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2007-07-06 16:44:09 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 3) THE FOOTING SECTION ON SHEET 1 FOR THE MONOLITHIC | | | SLAB AT THE PROPOSED ENCLOSED CARPORT DOES NOT SPECIFY | | | THE WIDTH AND HEIGHT DIMENSIONS OF THE FOOTER, THE | | | FOOTER REINFORCEMENT STEEL, THE HEIGHT ABOVE FINISH | | | GRADE OR THE DISTANCE FROM GRADE TO THE BOTTOM THE | | | FOOTING. SEE R404.1.6, R403.1.4 AND FBC106.1.2. | | | | | | 4) ON SHEET 2 THE NOTES FOR THE ROOF SHEATHING | | | INCORRECTLY SPECIFY 8D COMMON NAILS IN ROOF ZONES 1 AND | | | 2. SECTION R 803.2.3.1 REQUIRES RING SHANK NAILS IN ALL | | | ROOF ZONES. | | | | | | 5) THE ENERGY CALCULATION FORM THAT WAS SUBMITTED | | | SPECIFIES R-19 ATTIC INSULATION AND WALL SECTION 1 ON | | | SHEET A1 SPECIFIES R-30. PLEASE CORRECT. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|